User's Manual

Table Of Contents
4. Installation Procedures
RuggedMAX™ 26 Installation Guide Rev 1.0
Figure 4.14. Base Station Connectors wrapped with Splicing and Electrical Tape
Assembly without waterproof sealing tape or removing the waterproof sealing tape
from this device voids its warranty.
4.5. Hazardous Location Installation
This equipment is suitable for use in Class 1, Division 2, Groups A, B, C, D hazardous locations
only when installed using the Class 1, Division 2 installation kit (Ruggedcom P/N MKIT0090).
Explosion Hazard!
Do not connect the WIN1010 power supply in hazardous locations.
Do not substitute components.
Do not disconnect equipment unless power has been switched off or the area is
considered to be non-hazardous.
Use only the Lambda DPP50-48 power supply with the equipment.
RISQUE D’EXPLOSION
La substitution decomposants peut rendre ce matériel inacceptable pour les
emplacements de Classe I, Division 2.
Avant de déconnecter l’equipment, couper le courant ou s’assurer que
l’emplacement est désigné non dangereux.
Utilisez l’unité uniquement avec une batterie de la marque Lamba DPP50-48.
Contents of the Class 1, Division 2 Installation Kit:
Lambda power supply unit (model DPP50-48)
L-COM passive PoE injector (model BT-CAT5-P1)
DC cable for connection between the PSU and the PoE injector
To install the equipment in a hazardous location, do the following: