User's Manual
Table Of Contents
- Contents
- List of Tables
- List of Figures
- 1 Introduction and Important Notes
- 2 Overview
- 3 Planning a HiPath Cordless IP System
- 3.1 Planning According to Call Traffic Load
- 3.2 General
- 3.3 Propagation Conditions for Radio Traffic
- 3.4 Determining the Installation Site
- 3.5 Installing Base Stations
- 4 Putting Into Service
- 5 Installation and Administration
- 5.1 Terminology
- 5.2 Network Concept
- 5.3 Synchronisation over air concept
- 5.4 WBM related issues
- 5.5 Phone related issues
- 5.6 Partition concept of BSIP1
- 5.7 Factory reset of BSIP1
- 5.8 Release notes
- 5.9 Quick Start
- 5.10 Quick start overview
- 5.11 Prepare and connect hardware
- 5.12 Configure BSIP1 for IWU mode
- 5.13 Configuration of VoIP (Infrastructure) network
- 5.14 Configuration of DECT network
- 5.15 Configuration of users at the PBX
- 5.16 Configuration of users at the BSIP IWU
- 5.17 Start system services and register handsets
- 5.18 Configure further BSIP Only to the system
- 5.19 "Quick Start" Completion
- 5.20 Further steps
- 5.21 Configuration reference
- 5.22 WBM overview
- 5.23 Administration
- 5.24 "Network/Gateways" Configuration
- 5.25 "Group" Configuration
- 5.26 Users Configuration
- 5.27 Dect Configuration
- 5.27.1 Configuration Page "Dect - Device"
- 5.27.2 Configuration Page "Dect - Sync"
- 5.27.3 Configuration Page "Dect - ARI"
- 5.27.4 Configuration Page "Dect - About"
- 5.27.5 Configuration Page "Dect - Radio" (Advanced mode)
- 5.27.6 Configuration Page "Dect - Call" (Advanced mode)
- 5.27.7 Configuration Page "Dect - Debug" (Advanced mode)
- 5.27.8 General DECT configuration
- 5.28 Debugging Configuration
- 5.29 "Status" Configuration
- 5.30 "System" Configuration
- 5.31 Configuration Hints for PBXs
- 5.32 HiPath OpenOffice EE
- 5.33 HiPath OpenOffice ME
- 5.34 Troubleshooting / FAQ
- 5.35 Configuration hints for Web Browser
- 6 Technical Data
- 7 Diagnosis and Maintenance
- 8 Open Source Software used in the Product
- Index
c05_ikon.fm
Installation and Administration
Dect Configuration
A31003-C1010-S100-2-7620, 08/2010
HiPath Cordless IP, Service Manual 113
Name
The name of the Base Station can be configured here.
NumOfChannel
Number of voice channels of the Base Station in conjunction with the IWU.
The maximum value is "10". If less than "10" parallel voice channels shall be
supported, a smaller value may be configured here. The default value is "10".
IpAddr Module
The IP address of choice for the Base Station in the IP-DECT network is
entered here. Please take care that the "IpAddr Module" address has to be
unique and is in the same subnet as the IP address of the Interworking Unit
("Server Ip").
Please not that the IP address of the Base Station is transmitted to the Base
Station after a [UDP Set] (see chapter 5.27, “Dect Configuration”).
MAC Addr
In this field the ethernet MAC address of the Base Station is displayed as it is
found during a "Scan". It cannot be changed.
5.27.2 Configuration Page "Dect - Sync"
On this configuration page the synchronization of the Base Stations is confi-
gured.
The columns of the configuration page have the following meaning:
• Note: The columns "Enabled" and "Name" are repeated on all sub pages.
A description of thesevalues can be found in chapter 5.27.1, “Configu-
ration Page "Dect - Device"”.
"Sync" (Default value: "air")
Here you can configure the type of synchronization of the Base Station with a
dropdown box. It is important e.g. for the over air-synchronisation and
therefore for the seamless handover between basestations. You can choose
one of the following menu items in the dropdown box:
• "no": No synchronization of the Base Station. This may be configured if
no "seamless handover" is needed or if this BSIP serves as the “Sync
Master” which is the topmost synchronisation source.