User's Manual

Table Of Contents
c05_ikon.fm
Installation and Administration
"Status" Configuration
A31003-C1010-S100-2-7620, 08/2010
HiPath Cordless IP, Service Manual 127
5.29.2 Configuration Page "Status - Modules 2"
Module
This field contains the consecutive number of the BSIP 1.
Name
The name of the Base Station as read from the Base Station via "Scan".
Online
"Yes" if the selected Base Station is "Online".
ISyncCnt (In Sync Count)
Shows how often the Base Station did a resynchronisation since the start of
the system services.
OnlineCnt (Online Count)
Shows how often a Online/Offline change has been detected since the start
of the system services.
BootCnt (Boot Count)
Shows how often the Base Station was booted since the start of the system
services.
Outgoing calls
Shows how often an outgoing connection (from direction BSIP to PBX) has
been signalled.
Incoming calls
Shows how often an incoming connection (from direction PBX to DECT) has
been signalled.
Intracell handover
Shows how often a Intracell handover (transfer of a channel within the same
DECT Base Station ) was detected at the BSIP.
Intercell handover
Shows how often a Intercell handover (transfer of a channel between different
DECT ethernet Base Stations) was detected at the BSIP.