User's Manual
Table Of Contents
- Contents
- List of Tables
- List of Figures
- 1 Introduction and Important Notes
- 2 Overview
- 3 Planning a HiPath Cordless IP System
- 3.1 Planning According to Call Traffic Load
- 3.2 General
- 3.3 Propagation Conditions for Radio Traffic
- 3.4 Determining the Installation Site
- 3.5 Installing Base Stations
- 4 Putting Into Service
- 5 Installation and Administration
- 5.1 Terminology
- 5.2 Network Concept
- 5.3 Synchronisation over air concept
- 5.4 WBM related issues
- 5.5 Phone related issues
- 5.6 Partition concept of BSIP1
- 5.7 Factory reset of BSIP1
- 5.8 Release notes
- 5.9 Quick Start
- 5.10 Quick start overview
- 5.11 Prepare and connect hardware
- 5.12 Configure BSIP1 for IWU mode
- 5.13 Configuration of VoIP (Infrastructure) network
- 5.14 Configuration of DECT network
- 5.15 Configuration of users at the PBX
- 5.16 Configuration of users at the BSIP IWU
- 5.17 Start system services and register handsets
- 5.18 Configure further BSIP Only to the system
- 5.19 "Quick Start" Completion
- 5.20 Further steps
- 5.21 Configuration reference
- 5.22 WBM overview
- 5.23 Administration
- 5.24 "Network/Gateways" Configuration
- 5.25 "Group" Configuration
- 5.26 Users Configuration
- 5.27 Dect Configuration
- 5.27.1 Configuration Page "Dect - Device"
- 5.27.2 Configuration Page "Dect - Sync"
- 5.27.3 Configuration Page "Dect - ARI"
- 5.27.4 Configuration Page "Dect - About"
- 5.27.5 Configuration Page "Dect - Radio" (Advanced mode)
- 5.27.6 Configuration Page "Dect - Call" (Advanced mode)
- 5.27.7 Configuration Page "Dect - Debug" (Advanced mode)
- 5.27.8 General DECT configuration
- 5.28 Debugging Configuration
- 5.29 "Status" Configuration
- 5.30 "System" Configuration
- 5.31 Configuration Hints for PBXs
- 5.32 HiPath OpenOffice EE
- 5.33 HiPath OpenOffice ME
- 5.34 Troubleshooting / FAQ
- 5.35 Configuration hints for Web Browser
- 6 Technical Data
- 7 Diagnosis and Maintenance
- 8 Open Source Software used in the Product
- Index
Technical Data
c06.fm
Base Stations
A31003-C1010-S100-2-7620, 08/2010
158 HiPath Cordless IP, Service Manual
Accessories
6.3.1.4 Gigaset M2 Ex professional
• Weight incl. battery pack approx. 180 g
• Charging unit for EU including plug-in power supply unit S30852-H1786-R101
• Charging unit for UK including plug-in power supply unit S30852-H1786-L101
• Software Checking, see Section 7.2.2
• Output power Average output power +10 dBm per channel
Peak output power +24 dBm per channel
• Tone ringing
– Volume control adjustable: 5 levels, levels 4 and 5 for loud
environments.
– Tone ringing signal Can be configured separately for internal and
external calls
20 standard ringtones (3 ringtones / 17 melodies)
16 loadable polyphonic melodies
• User Interface (UI) Menu-driven graphic user interface
• Display Illuminated color display
• Telephone book
(integrated locally)
Up to a total of 250 entries
• Voice dialing
(voice telephone book)
Up to 30 entries
• PIN-lock • 4-digit, numeric (see Section 7.3.3)
• Full functionality of device
guaranteed for
-10 °C to +55 °C
100 % relative humidity including splashes and low
pressure jets of water (IP 65)
• Power supply (state of charge indicated on the display)
– Permitted Ex-battery pack Lithium-Ion, 1000 mAh including electronic
components (A5B00075609027)