User's Manual
Table Of Contents
- Contents
- List of Tables
- List of Figures
- 1 Introduction and Important Notes
- 2 Overview
- 3 Planning a HiPath Cordless IP System
- 3.1 Planning According to Call Traffic Load
- 3.2 General
- 3.3 Propagation Conditions for Radio Traffic
- 3.4 Determining the Installation Site
- 3.5 Installing Base Stations
- 4 Putting Into Service
- 5 Installation and Administration
- 5.1 Terminology
- 5.2 Network Concept
- 5.3 Synchronisation over air concept
- 5.4 WBM related issues
- 5.5 Phone related issues
- 5.6 Partition concept of BSIP1
- 5.7 Factory reset of BSIP1
- 5.8 Release notes
- 5.9 Quick Start
- 5.10 Quick start overview
- 5.11 Prepare and connect hardware
- 5.12 Configure BSIP1 for IWU mode
- 5.13 Configuration of VoIP (Infrastructure) network
- 5.14 Configuration of DECT network
- 5.15 Configuration of users at the PBX
- 5.16 Configuration of users at the BSIP IWU
- 5.17 Start system services and register handsets
- 5.18 Configure further BSIP Only to the system
- 5.19 "Quick Start" Completion
- 5.20 Further steps
- 5.21 Configuration reference
- 5.22 WBM overview
- 5.23 Administration
- 5.24 "Network/Gateways" Configuration
- 5.25 "Group" Configuration
- 5.26 Users Configuration
- 5.27 Dect Configuration
- 5.27.1 Configuration Page "Dect - Device"
- 5.27.2 Configuration Page "Dect - Sync"
- 5.27.3 Configuration Page "Dect - ARI"
- 5.27.4 Configuration Page "Dect - About"
- 5.27.5 Configuration Page "Dect - Radio" (Advanced mode)
- 5.27.6 Configuration Page "Dect - Call" (Advanced mode)
- 5.27.7 Configuration Page "Dect - Debug" (Advanced mode)
- 5.27.8 General DECT configuration
- 5.28 Debugging Configuration
- 5.29 "Status" Configuration
- 5.30 "System" Configuration
- 5.31 Configuration Hints for PBXs
- 5.32 HiPath OpenOffice EE
- 5.33 HiPath OpenOffice ME
- 5.34 Troubleshooting / FAQ
- 5.35 Configuration hints for Web Browser
- 6 Technical Data
- 7 Diagnosis and Maintenance
- 8 Open Source Software used in the Product
- Index
Overview
c02.fm
DECT IP Base Station Data
A31003-C1010-S100-2-7620, 08/2010
26 HiPath Cordless IP, Service Manual
2.3.1 Outdoor Case
A DECT IP base station must be installed in a weatherproof outdoor case to
guarantee radio coverage in outdoor areas, for example on factory sites. The
outdoor case is suitable for mounting on house walls, roofs or masts.
The outdoor case already used for the HiPath Cordless base station BS4 is also
used for DECT IP base stations (part number: S30122-X7469-X2).
If using the DECT IP base station outdoors, lightning and overvoltage protection
must be provided and guaranteed for the DECT IP base station itself as well as
for the feeder into the DECT IP base station and the building. In compliance with
EN 61000-4-5, the power supply inlet on the DECT IP base station offers up to
0.5 KV overvoltage protection.
Figure 7 Outdoor case with DECT IP base station
Outdoor Case