Overview
Load monitoring for 3RF2 single-phase solid-state switching
devices
Many faults can be quickly detected by monitoring a load circuit
connected to the solid-state switching device, as made possible
with this module. Examples include the failure of load elements
(up to 6 in the basic version or up to 12 in the extended version),
alloyed power semiconductors, a lack of voltage or a break in a
load circuit. A fault is indicated by one or more LEDs and re-
ported to the controller by way of a PLC-compatible output.
The principle of operation is based on permanent monitoring of
the current intensity. This figure is continuously compared with
the reference value stored once during start-up by the simple
press of a button. In order to detect the failure of one of several
loads, the current difference must be 1/6 (in the basic version) or
1/12 (in the extended version) of the reference value. In the event
of a fault, an output is actuated and one or more LEDs indicate
the fault.
Application
The device is used for monitoring one or more loads (partial
loads). The function module can only be used in conjunction with
a 3RF21 solid-state relay or a 3RF23 solid-state contactor. The
devices with spring-type connections in the load circuit are not
suitable.
Selection and ordering data
Rated operational current
I
e
Rated operational voltage
U
e
DT Screw terminals PU
(UNIT,
SET, M)
PS* PG
AV
Order No. Price
per PU
Basic load monitoring
3RF29
Rated control supply voltage 24 V DC
6-- A
3RF29 06-0FA08 1 1 unit 101
20 -- A
3RF29 20-0FA08 1 1 unit 101
With mounted 3RF29 00-0RA88 cover
6-- A3RF29 06-0FA08-0KH0 1 1 unit 101
20 -- A
3RF29 20-0FA08-0KH0 1 1 unit 101
Extended load monitoring
3RF29
Rated control supply voltage 24 V AC/DC
20 110 … 230 A
3RF29 20-0GA13 1 1 unit 101
20 400 … 600 A
3RF29 20-0GA16 1 1 unit 101
50 110 … 230 A
3RF29 50-0GA13 1 1 unit 101
50 400 … 600 A
3RF29 50-0GA16 1 1 unit 101
90 110 … 230 A
3RF29 90-0GA13 1 1 unit 101
90 400 … 600 A
3RF29 90-0GA16 1 1 unit 101
Rated control supply voltage 110 V AC
20 110 … 230 A
3RF29 20-0GA33 1 1 unit 101
20 400 … 600 A
3RF29 20-0GA36 1 1 unit 101
50 110 … 230 A
3RF29 50-0GA33 1 1 unit 101
50 400 … 600 A
3RF29 50-0GA36 1 1 unit 101
90 110 … 230 A
3RF29 90-0GA33 1 1 unit 101
90 400 … 600 A
3RF29 90-0GA36 1 1 unit 101
Version DT Order No. Price
per PU
PU
(UNIT,
SET, M)
PS* PG
Optional accessories
3RF29 00-0RA88
Sealable covers
for function modules (not for converters)
B
3RF29 00-0RA88 1 10 units 101
© Siemens AG 2010