Data Sheet

Degree of pollution 3
Protection class IP IP20
Shock resistance / acc. to IEC 60068-2-27 15g / 11 ms
Vibration resistance / acc. to IEC 60068-2-6 2g
Reference code / acc. to DIN 40719 extended
according to IEC 204-2 / acc. to IEC 750
K
Reference code / acc. to DIN EN 81346-2 Q
Reference code / acc. to DIN EN 61346-2 Q
Main circuit
Number of poles / for main current circuit 1
Number of NO contacts / for main contacts 1
Number of NC contacts / for main contacts 0
Operating voltage / at AC
● at 50 Hz / rated value
48...460V
● at 60 Hz / rated value
48...460V
Operating frequency / rated value 50...60Hz
Operating range relative to the operating voltage / at
AC
● at 50 Hz
40...506V
● at 60 Hz
40...506V
Operating current / minimum 100mA
Operating current
● at AC-1 / at 400 V / rated value
10.5A
● at AC-51 / rated value
10.5A
Rate of voltage rise / at the thyristor / for main
contacts / maximum permissible
500V/µs
Blocking voltage / at the thyristor / for main contacts /
maximum permissible
1200V
Reverse current / of the thyristor 10mA
Derating temperature 40°C
Surge current resistance / rated value 200A
I2t value / maximum 200A²·s
Control circuit/ Control
Type of voltage / of the control supply voltage DC
Control supply voltage / 1
● at DC / rated value
30V
● at DC
4...30V
Control supply voltage
● at DC / initial value for signal <1> detection
4V
● at DC / Full-scale value for signal<0>
recognition
1V
Control current / at DC / rated value 20mA
Switch-on delay time 1ms; additionally max. one half-wave
3RF2310-1AA44 Subject to change without notice
Page 2/
7
09/13/2019 © Copyright Siemens