Datasheet

10/44
Siemens IC 10 · 2015
Relays
Timing Relays
SIRIUS 3RP25 timing relays, 17.5 mm and 22.5 mm
10
Setting the functions on the device
Overview of functions of the 3RP2505 multifunctional timing relay
Two setting options for implementing the multifunctions (A-M):
Extended function variance by selecting the time range and determining,
whether 2 CO switch in parallel or
whether 1 CO switches with delay + 1 CO switches immediately (1 CO + 1 CO)
Determination of 13 functions by the setting A to M,
with 1 CO, 1 NO, 2 CO that switch in parallel.
2
1
1
2
IC01_00353
Identification letter 13 functions 27 functions
1 CO, 1 NO (semiconductor) or
2 CO switched in parallel
13 functions (A - M) 2 CO switched in parallel +
13 functions (A - M) 1 CO delayed + 1 CO instantaneous
(1 CO + 1 CO) and wye-delta function
A ON-delay ON-delay and instantaneous contact
B OFF-delay with control signal OFF-delay with control signal and instantaneous contact
C ON-delay/OFF-delay with control signal ON-delay/OFF-delay with control signal and instantaneous contact
D Flashing, symmetrical, starting with interval Flashing, symmetrical, starting with interval and instantaneous
contact
E Passing make contact, interval relay Passing make contact, interval relay and instantaneous contact
F Retriggerable interval relay with deactivated control signal
(passing break contact with control signal)
Retriggerable interval relay with deactivated control signal
(passing break contact with control signal) and instantaneous
contact
G Passing make contact, with control signal, not retriggerable
(pulse-forming with control signal)
Passing make contact, with control signal, not retriggerable
(pulse-forming with control signal) and instantaneous contact
H Additive ON-delay, instantaneous OFF with control signal Additive ON-delay, instantaneous OFF with control signal and
instantaneous contact
I Additive ON-delay with control signal Additive ON-delay with control signal and instantaneous contact
J Flashing, symmetrical, starting with pulse Flashing, symmetrical, starting with pulse and instantaneous
contact
K Pulse-delayed (fixed pulse (at 1 s) and settable pulse delay) Pulse-delayed (fixed pulse (at 1 s) and settable pulse delay)
and instantaneous contact
L Pulse-delayed with control signal (fixed pulse (at 1 s) and settable
pulse delay)
Pulse-delayed with control signal (fixed pulse (at 1 s) and settable
pulse delay) and instantaneous contact
M Retriggerable interval relay with activated control signal (watchdog) Retriggerable interval relay with activated control signal and
instantaneous contact (watchdog)
-- -- Wye-delta function
© Siemens AG 2015