Data Sheet

● at AC-15 at 230 V typical
100000
Adjustable time 1...20s
Relative setting accuracy relating to full-scale value 5%
Thermal current 5A
Recovery time 300ms
Reference code acc. to DIN 40719 extended
according to IEC 204-2 acc. to IEC 750
K
Reference code acc. to DIN EN 81346-2 K
Reference code acc. to DIN EN 61346-2 K
Relative repeat accuracy 1%
Control circuit/ Control
Type of voltage of the control supply voltage AC/DC
Control supply voltage 1 at AC
● at 50 Hz
12...240V
● at 60 Hz
12...240V
Control supply voltage frequency 1 50...60Hz
Control supply voltage 1
● at DC
12...240V
Operating range factor control supply voltage rated
value at DC
● initial value
0.85
● Full-scale value
1.1
Operating range factor control supply voltage rated
value at AC at 50 Hz
● initial value
0.85
● Full-scale value
1.1
Operating range factor control supply voltage rated
value at AC at 60 Hz
● initial value
0.85
● Full-scale value
1.1
Inrush current peak
● at 24 V
0.5A
● at 240 V
5A
Duration of inrush current peak
● at 24 V
0.4ms
● at 240 V
0.5ms
Switching Function
Switching function
● ON-delay
No
● ON-delay/instantaneous contact
No
● passing make contact
No
● passing make contact/instantaneous contact
No
3RP2560-1SW30 Subject to change without notice
Page 2/
8
09/12/2019 © Copyright Siemens