Datasheet

Power Contactors for Switching Motors
3/13
Siemens IC 10 AO · 2013
SIRIUS 3RT10 contactors,
3-pole, 3 ... 250 kW
3
Version 3RT1. . .-.P: for 24 V DC PLC output or
PLC relay output, with remaining lifetime indicator (RLT).
To supply the solenoid and the remaining lifetime indicator with
power, the control supply voltage U
s
must be connected to ter-
minals A1/A2 of the laterally mounted solid-state module. The
control inputs of the contactor are connected to a 7-pole plug-in
connection; the screwless spring-type connection is part of the
scope of supply.
The "Remaining Lifetime RLT
" status signal is available at ter-
minals R1/R2 through a floating relay contact (hard gold-
plated, enclosed) and can be input to SIMOCODE, PLC or
other devices for processing, for example.
Permissible current-carrying capacity of the R1/R2 relay out-
put:
- I
e
/AC-15/24 to 230 V: 3 A
- I
e
/DC-13/24 V: 1 A
LED displays
The following states are indicated by means of LEDs on the
laterally mounted solid-state module:
- Contactor ON (energized state): green LED ("ON")
- Indication of remaining lifetime
2 control options:
7 Contactor control without a coupling link directly through a 24
V DC/ 30 mA PLC output (IEC 61131-2) by way of terminals
IN+/IN-.
Possibility of switching from automatic control to local control by
way of terminals H1/H2, i.e. automatic control through PLC or SI-
MOCODE/PROFIBUS DP can be deactivated e.g. at start-up or
in the event of a fault and the contactor can be controlled man-
ually.
7 Contactor control through relay outputs at connections H1/H2,
e.g. by
- PLC or
-SIMOCODE
Contact loading: U
s
/approx. 5 mA.
When operated through SIMOCODE, a communication link to
PROFIBUS DP is also provided.
Order No. scheme
The Order No. scheme is presented here merely for information
purposes and for better understanding of the logic behind the
order numbers.
For your orders, please use the order numbers quote in the cat-
alog and in the Industry Mall.
ON
H1
H2
R1
R2
IN
IN
24 V
DC
RLT
300 V
AC/DC
A1
A2
-.PP3.
200-277 V
50-60 Hz
DC
RLT
60 %
40 %
20 %
Reset
3RT105/3RT145
NSB0_01145b
Contactor ON
Displays for RLT:
LED green
LED green
LED orange
LED red
RLT Reset
Plug-in
connection
7-pole
2
1
S2
S1
PLC output
24 V DC/30 mA
lifetime 20 %
Signal for remaining
2
1
On-site control possibility
Changeover switch from auto-
matic control using PLC semicon-
ductor output to on-site control
Plug-in connection, 7-pole
Solid-state module of
contactor 3RT1...-.P
2
1
3
Shutdown in an emergency
(EMERGENCY-STOP) – optional
3
NSB0_01146f
H2
IN
IN
R2
R1
H1
S1
S1
S2
A2A1
N/L-
L1/L+
S1
S2
1
2
3
Signal for remaining
lifetime 20 %
PLC
other
SIMOCODE
e. g.
On-site control possibility
S2
S1
Changeover switch from auto-
matic control e.g. using
SIMOCODE or PLC relay output to
on-site control
Plug-in connection, 7-pole
Shutdown in an emergency
(EMERGENCY-STOP) – optional
3
Solid-state module of
contactor 3RT1...-.P
2
1
PROFIBUS DP
NSB0_01147e
IN
IN
R2
R1
H2
H1
A2A1
N/L-
L1/L+
Digit of the Order No. 1. - 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16.
@@@ @ @ @ @ @ @ @ @ @ @ @ @ @
SIRIUS power contactors 3 R T
1. generation 1
Device type (e. g. 0 = 3-pole motor contactor, 3 = 4-pole AC-1 contactor) @
Size of the contactor (3 = S2, 4 = S3, 5 = S6, etc.) @
Power dependent on size (e.g. 45 = 37 kW) @
Connection type (1 = screw, 2 = spring) @
Operating range / solenoid coil circuit (e. g. A = AC standard / without) @
Rated control supply voltage (e. g. P0 = 230 V, 50 Hz) @ @
Auxiliary switches (e.g. S3: 0 = without auxiliary switches @
Special version @ @ @ @
Example 3 R T 1 0 4 5 1 A P 0 0
© Siemens AG 2012