Datasheet
Protection class IP IP66/IP67
Shock resistance
● acc. to IEC 60068-2-27
30 g / 11 ms
Vibration resistance
● acc. to IEC 60068-2-6
0.35 mm/5g
Mechanical service life (switching cycles)
● typical
15000000
Electrical endurance (switching cycles)
● at AC-15 at 230 V typical
100000
Electrical endurance (switching cycles) with contactor
3RH11, 3RT1016, 3RT1017, 3RT1024, 3RT1025,
3RT1026 typical
10000000
Electrical operating cycles in one hour with contactor
3RH11, 3RT1016, 3RT1017, 3RT1024, 3RT1025,
3RT1026
6000
Thermal current 10A
Material of the enclosure of the switch head plastic
Continuous current of the C characteristic MCB 1A; for a short-circuit current smaller than 400 A
Continuous current of the quick DIAZED fuse link 10A; for a short-circuit current smaller than 400 A
Continuous current of the DIAZED fuse link gG 6A
Active principle mechanical
Repeat accuracy 0.05mm
Minimum actuating force in activation direction 20N
Length of the sensor 103.5mm
Width of the sensor 40mm
Design of the switching contact mechanical
Operating frequency rated value 50...60Hz
Number of NC contacts for auxiliary contacts 1
Number of NO contacts for auxiliary contacts 1
Number of CO contacts for auxiliary contacts 1
Operating current at AC-15
● at 24 V rated value
6A
● at 125 V rated value
6A
● at 240 V rated value
6A
● at 400 V rated value
4A
Operating current at DC-13
● at 24 V rated value
3A
● at 125 V rated value
0.55A
● at 250 V rated value
0.27A
● at 400 V rated value
0.12A
Design of the interface for safety-related
communication
without
Enclosure
3SE5132-0CC03 Subject to change without notice
Page 2/
7
12/14/2018 © Copyright Siemens