Datasheet

Electrical operating cycles as operating time
• with contactor 3RH11, 3RT1016, 3RT1017, 3RT1024, 3RT1025,
3RT1026 / typical
500,000
• at AC-15 / at 230 V / typical 100,000
Electrical operating cycles in one hour
• with contactor 3RH11, 3RT1016, 3RT1017, 3RT1024, 3RT1025,
3RT1026
1,800
Repeat accuracy mm 0.05
Design of the contact element snap-action contacts
Number of NC contacts
• for auxiliary contacts 1
Design of the switching function snap-action contact
Number of NO contacts
• for auxiliary contacts 1
Resistance against vibration 0.35 mm / 5g
Resistance against shock 30g / 11 ms
Ambient temperature
• during operating °C -25 … +85
• during storage °C -25 … +85
Width of the sensor mm 30
Material
• of the enclosure metal
Material / of the housing / of the switch head stainless steel
Design of the operating mechanism roller plunger
Actuating speed mm/s / m/s 0.05 … 2
Minimum actuating force / in activation direction N 15
Protection class IP IP67
mounting position any
Design of the electrical connection cable connection 5x 0.75 m2 PVC
Item designation
• according to DIN 40719 extendable after IEC 204-2 S
• according to DIN EN 61346-2 B
Certificates/approvals:
General Product
Approval
other
Confirmation
Further information:
3SE5413-0CD20-1EA2
Page 2/ 03/08/2013
subject to modifications
© Copyright Siemens AG 2013
4