User Manual

3SU14 modules
7.1 Overview
SIRIUS ACT 3SU1 pushbuttons and signaling devices
136 System Manual, 02/2015, A5E03457306020A/RS-AB/002
7.1.2
Contact modules for enclosure (base) mounting
The contact modules for enclosure mounting are installed in 3SU18 enclosures.
For further information refer to Chapter "3SU18 enclosures (Page 147)"
Number of NO contacts
Number of NC contacts
Product function
positive opening
Article number
3SU1400-2AA10 (http://mall.industry.siemens.com/mall/en/en/Catalog/Products/10227974)
1 0 No 3SU1400-2AA10-xBA0
0
1
Yes
3SU1400-2AA10-xCA0
x: 1 = screw terminals
x: 3 = spring-loaded terminals
7.1.3
LED modules
Only LED modules with permanently integrated LEDs are available for illuminating the 3SU1
pushbuttons and signaling devices.
These devices are available in different variants according to the following features:
Spring-loaded terminals
Screw terminals
PCB installation
Front plate mounting
Base mounting (enclosure mounting)
Colors
Voltages
LED modules bear terminal designations in accordance with EN 50013.