Information

13/17
Siemens IC 10 · 2018
SIRIUS ACT Pushbuttons and Indicator Lights
General data
13
Type 3SU1.5.-2A
3SU1.5.-2B
3SU1.5.-2C
3SU1.5.-2D
3SU1.5.-2E
3SU1.0.-2A
3SU1.0.-2B
3SU1.0.-2C
3SU1.3.-2A
3SU1.3.-2B
3SU1.3.-2C
3SU1.0.-3E
3SU1.3.-3E
3SU1.5.-3E
3SU1.0.-4B
3SU1.0.-4C
3SU1.0.-4D
3SU1.0.-4F
3SU1.0.-4G
3SU1.0.-4H
3SU1.0.-4J
3SU1.0.-4L
3SU1.0.-5B
3SU1.0.-5H
3SU1.0.-5P
3SU1.0.-5Q
3SU1.0.-5R
3SU1.0.-5S
3SU1.0.-5T
3SU1.0.-5X
3SU1...-4B
3SU1...-4C
3SU1...-4D
3SU1...-4F
3SU1...-4G
3SU1...-4H
3SU1...-4J
3SU1...-4L
3SU1...-5B
3SU1...-5H
3SU1...-5K
3SU1...-5L
3SU1...-5P
3SU1...-5Q
3SU1...-5R
3SU1...-5S
3SU1...-5T
3SU1...-5X
3SU1.0.-7A
3SU1.0.-7B
3SU1.3.-7A
3SU1.3.-7B
3SU1.5.-7A
3SU1.5.-7B
Product version
Selector switches Toggle
switches
Key-operated switches Coordinate
switches
Mechanical endurance (operating cycles)
300 000 1 000 000 300 000 250 000
Switching frequency maximum 1/h
1 800 3600
Shock resistance acc. to IEC 60068-2-27
Half-sine wave 50 g/11 ms
Vibration resistance acc. to IEC 60068-2-6 10 ... 500 Hz: 5 g
Degree of protection IP66, IP67, IP69 (IP69K) IP66, IP67,
IP69K
IP66, IP67, IP69 (IP69K) IP65, IP67
Ambient temperature
During operation
°C
-25 +70
During storage
°C
-40 +80
Type 3SU1400-
.AA10-1A.0
3SU1400-
1AA10-1GA0,
3SU1400-
1AA10-1RA0
3SU1400-
1AA10-1HA0
3SU1400-
.AA10-3A.0
3SU1400-
1AA10-3HA0
3SU1400-
3AA10-5A.0
Product version Contact modules
Rated insulation voltage V
500
Pollution degree 3
Impulse withstand voltage
rated value
kV 6
Operational voltage type AC/DC
Operational voltage, rated value
At AC at 50 Hz
V
5…500
•At DC
V
5…500
Thermal current A 10
Operational current, rated value
At AC-12
- At 24 V A 10
- At 230 V A 8
•At AC-15
- At 24 V A 6
- At 230 V A 6 4 6 6
- At 400 V A
3
- At 500 V A 1.4
At DC-12
- At 24 V A 10
- At 48 V A 5
- At 110 V A 2.5
- At 230 V A 1 0.3 1 0.3 1
- At 400 V A
0.3
- At 500 V A 0.3 0.2 0.3
At DC-13
- At 24 V A 3
- At 48 V A 1.5
- At 110 V A 0.7 0.6 0.7 0.6 0.7
- At 230 V A
0.3
- At 400 V A 0.1
- At 500 V A 0.1
Contact reliability One contact failure per 100 million switching operations (17 V, 5 mA),
one contact failure per 10 million switching operations (5 V, 1 mA)
Mechanical endurance (operating cycles) typical
10 000 000
© Siemens AG 2017