User Manual

IO-Link
10.2 Design of a command point with ID key-operated switch
SIRIUS ACT 3SU1 pushbuttons and signaling devices
System Manual, 02/2015, A5E03457306020A/RS-AB/002
219
Settings
Description
Default setting
0
Switch position memory: disabled
Disabled
1 Switch position memory: enabled
10.2.3.4
"Key memory" parameter
"Key memory" parameter
Prerequisite:
The "Key memory" parameter only functions in combination with the "Switch position
memory" parameter. The "Switch position memory" parameter must be enabled.
1) "Key memory" disabled:
After shutting down the power supply of the electronic module, the last current switch
position is lost, and the module is set to 0 after switching on again
2) "Key memory" enabled:
After shutting down the power supply of the electronic module, the last current switch
position is saved to the permanent memory and renewed after the electronic module is
switched on again.
Settings
Description
Default setting
0
Key memory: disabled
Disabled
1
Key memory: enabled
10.2.3.5
"Individual keys only" parameter
"Individual keys only" parameter
1) "Individual keys only" disabled:
All authorization levels are activated.
2) "Individual keys only" enabled:
Only individually encodable ID keys are permitted. In this case, only individually
encodable ID keys are detected, regardless of whether they are listed in the key list in the
electronic module or not. The ID groups 1 ... 4 are ignored.
Settings
Description
Default setting
0
Individual keys only: disabled
Disabled
1 Individual keys only: enabled