Check whether the rated voltage of the power supply corresponds to the values in the section
"Technical specifications".
CAUTION
Safety extra low voltage
The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited
Power Source (LPS). (This does not apply to 100 V...240 V devices.)
This means that only SELV / LPS complying with IEC 60950‑1 / EN 60950‑1 / VDE 0805‑1
must be connected to the power supply terminals, or the power supply unit for the equipment
power supply must comply with NEC Class 2, as described by the National Electrical Code (r)
(ANSI / NFPA 70).
6.3.2.2 Ethernet
When installing and connecting the Ethernet connection, observe the applicable general
conditions and their legal basis.
The Ethernet connection is connected to the Ethernet socket of the device. The cable must be
connected to the RJ45 plug before connection to the socket.
6.3.3 Technical specifications
Table 6-9 Technical specifications of the gateway RTLS4420G
6GT2701-2CB02
Product name SIMATIC RTLS4420G
Wireless frequencies
Wireless method IEEE 802.15.4a nanoLOC - Chirp Spread Spectrum (CSS)
Transmission speed 1 Mbps
Operating frequency 2400 ... 2480 MHz
Operating frequency rated value 2.45 GHz ISM band
Transmit power 0.00025 ... 100 mW
Range Max. 1000 m
Accuracy of the localization 1.5 m
Chirp bandwidth 80 MHz
Range with 1 Mb Inside maximum 90 m
Outside maximum 1000 m (typical 500 m)
Ethernet
Interfaces 10/100 MBit
Gateways