System Manual
Table Of Contents
- SIMATIC RTLS Hardware
- Legal information - Warning notice system
- Table of contents
- 1 Introduction
- 2 Safety notices
- 3 System overview
- 4 Planning an RTLS system
- 5 Anchors
- 5.1 SIMATIC RTLS4030A
- 5.2 SIMATIC RTLS4330A
- 5.3 SIMATIC RTLS4420A
- 5.4 SIMATIC RTLS4430A
- 6 Gateways
- 6.1 SIMATIC RTLS4030G
- 6.2 SIMATIC RTLS4330G
- 6.3 SIMATIC RTLS4420G
- 6.4 SIMATIC RTLS4430G
- 7 Transponder
- 7.1 SIMATIC RTLS4030T
- 7.2 SIMATIC RTLS4060T
- 7.3 SIMATIC RTLS4083T
- 7.4 SIMATIC RTLS4084T
- 7.5 SIMATIC RTLS4460T
- 7.6 SIMATIC RTLS PCB OEM AC
- 7.7 SIMATIC RTLS PCB OEM AX
- 7.8 SIMATIC RTLS PCB OEM CHIRP
- 7.9 SIMATIC RTLS PCB OEM PULSE
The labeling of electrical equipment is as follows:
LISTED E223122
IND.CONT.EQ FOR HAZ.LOC.
CL.I, DIV.2, GP.C,D T4
CL.II, DIV.2, GP.F,G T80 °C
AEx ec IIB T4 Gc, Ex ec IIB T4 Gc X
AEx tc IIIC TXX °C Dc, Ex tc IIIC TXX °C Dc X
-40 °C < Tamb. < +70 °C
IP40
U
n
= 24 V DC, 200 mA
The equipment also carries the following notes:
XXXYYYZZZ [= serial number, is assigned during production]
6.4 SIMATIC RTLS4430G
6.4.1 Device description
6.4.1.1 Characteristics
SIMATIC RTLS4430G Characteristics
1
3
2
Design ① Status indicators (LEDs)
② Connector for power supply
③ Ethernet port;
Alternative power supply using Power over
Ethernet (PoE)
General The device is the home location for localiza‐
tion in the RTLS localization system.
It can be connected to the local IT infrastruc‐
ture over Ethernet. This connection sets up an
exchange between the node, the localization
network and the localization server.
Area of application The device is suitable for use in damp envi‐
ronments.
Supply voltage The device can be operated with 8 to 30 V DC.
Gateways
6.4 SIMATIC RTLS4430G
System Manual, 04/2019, C79000-G8976-C577-01 109