System Manual

Table Of Contents
A gateway is ready for operation when both the upper green LED and the lower blue LED light
up permanently. The third (middle) LED plays no role in operational readiness.
6.4.2.5 Cleaning and maintenance
The device may only be opened by suitably trained and qualified personnel. Only authorized
dealers are permitted to repair the device.
Unauthorized opening of and improper repairs to the device may cause substantial risks to the
user. As soon as the device was opened without permission, warranty and liability of the
Siemens AG are rendered null and void.
Do not clean the enclosure with abrasive, alkaline or aggressive cleaning products or aids.
6.4.3 Technical specifications
Table 6-12 Technical specifications of the gateway RTLS4430G
6GT2701-5CB02
6GT2701-5CB02-0AX0
Product name SIMATIC RTLS4430G
Wireless frequencies
Wireless method IEEE 802.15.4a
Transmission speed 1 Mbps
Operating frequency 2400 ... 2480 MHz
Operating frequency rated value 2.45 GHz ISM band
Transmit power 0.00025 ... 100 mW
Range Max. 1000 m
Accuracy of the localization 1.5 m
Antennas Built-in 2.4 GHz antenna
Ethernet
Ethernet 10/100 Mbit auto-detect
Duplex mode Half or full duplex
DHCP Yes
PoE IEEE 802.3af class 0,
Power rating 0.44 … 12.94 W
Supply voltage, power consumption
Supply voltage 8 ... 30 V DC
Rated voltage 24 V DC
Power consumption Max. 5 W
Current consumption Max. 0.63 A
Gateways
6.4 SIMATIC RTLS4430G
118 System Manual, 04/2019, C79000-G8976-C577-01