System Manual
Table Of Contents
- SIMATIC RTLS Hardware
- Legal information - Warning notice system
- Table of contents
- 1 Introduction
- 2 Safety notices
- 3 System overview
- 4 Planning an RTLS system
- 5 Anchors
- 5.1 SIMATIC RTLS4030A
- 5.2 SIMATIC RTLS4330A
- 5.3 SIMATIC RTLS4420A
- 5.4 SIMATIC RTLS4430A
- 6 Gateways
- 6.1 SIMATIC RTLS4030G
- 6.2 SIMATIC RTLS4330G
- 6.3 SIMATIC RTLS4420G
- 6.4 SIMATIC RTLS4430G
- 7 Transponder
- 7.1 SIMATIC RTLS4030T
- 7.2 SIMATIC RTLS4060T
- 7.3 SIMATIC RTLS4083T
- 7.4 SIMATIC RTLS4084T
- 7.5 SIMATIC RTLS4460T
- 7.6 SIMATIC RTLS PCB OEM AC
- 7.7 SIMATIC RTLS PCB OEM AX
- 7.8 SIMATIC RTLS PCB OEM CHIRP
- 7.9 SIMATIC RTLS PCB OEM PULSE
Pin Description Color of the cable core
4 Digital input 2 Orange
5 Digital input 1 Yellow
6 CAN L Green
7 CAN H Blue
8 Not used Violet
Digital output
Both digital device outputs can switch resistive, capacitive and inductive loads. The current is
automatically limited to these functions.
The following must be observed for inductive loads (e.g. relays): Inductivities up to 32 H can be
switched off without freewheeling diode D
V
. A freewheeling diode D
V
is required for higher
inductivities.
If a freewheeling diode D
V
is used, an additional polarity protection diode D
P
must be inserted.
Digital input
The device has 2 digital inputs. Each has a range from 0 to 24 V with an impedance of 4.7 kOhm.
Transponder
7.2 SIMATIC RTLS4060T
134 System Manual, 04/2019, C79000-G8976-C577-01