7.3.1.4 Dimension drawing
)
6,0$7,&
57/67
Figure 7-3 Dimension drawing SIMATIC RTLS4083T - All dimensions specified in millimeters
7.3.2 Installation & Operation
7.3.2.1 Notes on installation
Before you install the devices, read this section carefully to ensure trouble-free installation and
operation.
The devices can only be used in conjunction with the RTLS localization system. Setup,
installation and use of the tools and clients of the RTLS localization system are described in the
corresponding manuals.
Mount the device so that it has a direct line-of-sight connection to the anchors/gateways (360°
panorama view). Any type of material can impact localization. Localization through metal is not
possible. Localization through radio reflections is possible in this case which results in an
inaccurate localization.
Check the device for damages before you use it so that it is not damaged during operation.
Protect the display from objects that could scratch or otherwise damage it. The specified
operating temperature ranges must be observed.
The device contains a lithium battery.
CAUTION
Fires and burns
Improper handling of batteries can lead result in fires and burns.
Transponder
7.3 SIMATIC RTLS4083T