The housing of the device must not be squashed, punctured or exposed to other mechanical
influences.
Never expose the device to fire, temperatures above 50 °C or direct sunlight for an extended
period of time.
7.3.2.2 Operation
The device is operated with a button on the front panel. The function of the button can be
programmed with the software.
7.3.2.3 Cleaning and maintenance
The housing must not be opened.
The device may only be repaired by an authorized maintenance company or opened for other
types of work.
Improper opening or repairing of the device may result in risks for the user. Opening the device
without permission renders the warranty of the Siemens AG null and void.
Do not clean the enclosure with liquids or abrasive, caustic or flammable cleaning products.
7.3.3 Technical specifications
Table 7-8 Technical specifications of the transponder RTLS4030T
6GT2700-5DC03
Product name SIMATIC RTLS4083T
PULSE radio frequencies (localization)
Wireless method IEEE 802.15.4-2011 UWB
Transmission speed 6.8 Mbps
Operating frequency rated value 3100 MHz … 4800 MHz
6000 MHz … 7000 MHz
Transmit power 0.037 mW (-41.3 dBm/MHz)
Range Max. 30 m
Accuracy of the localization 0.2 m
Antennas Built-in UWB antenna
PHASE radio frequencies (communication and optional local‐
ization)
Wireless method IEEE 802.15.4
Transmission speed 1 Mbps
Operating frequency rated value 2400 ... 2480 MHz
Transmit power Max. 4 dBm (can be set)
Transponder
7.3 SIMATIC RTLS4083T
144 System Manual, 04/2019, C79000-G8976-C577-01