System Manual
Table Of Contents
- SIMATIC RTLS Hardware
- Legal information - Warning notice system
- Table of contents
- 1 Introduction
- 2 Safety notices
- 3 System overview
- 4 Planning an RTLS system
- 5 Anchors
- 5.1 SIMATIC RTLS4030A
- 5.2 SIMATIC RTLS4330A
- 5.3 SIMATIC RTLS4420A
- 5.4 SIMATIC RTLS4430A
- 6 Gateways
- 6.1 SIMATIC RTLS4030G
- 6.2 SIMATIC RTLS4330G
- 6.3 SIMATIC RTLS4420G
- 6.4 SIMATIC RTLS4430G
- 7 Transponder
- 7.1 SIMATIC RTLS4030T
- 7.2 SIMATIC RTLS4060T
- 7.3 SIMATIC RTLS4083T
- 7.4 SIMATIC RTLS4084T
- 7.5 SIMATIC RTLS4460T
- 7.6 SIMATIC RTLS PCB OEM AC
- 7.7 SIMATIC RTLS PCB OEM AX
- 7.8 SIMATIC RTLS PCB OEM CHIRP
- 7.9 SIMATIC RTLS PCB OEM PULSE
Unauthorized opening of and improper repairs to the device may cause substantial risks to the
user. As soon as the device was opened without permission, warranty and liability of the
Siemens AG are rendered null and void.
Do not clean the enclosure with abrasive, alkaline or aggressive cleaning products or aids.
7.6.3 Technical specifications
Table 7-15 Technical specifications of the transponder RTLS PCB OEM AC
6GT2700-8DF00-0AX1
Product name SIMATIC RTLS PCB OEM AC
PULSE radio frequencies (localization)
Wireless method IEEE 802.15.4-2011 UWB
Transmission speed 6.8 Mbps
Operating frequency rated value 3100 MHz … 4800 MHz
6000 MHz ... 7000 MHz
Transmit power 0.037 mW (-41.3 dBm/MHz)
Range Max. 30 m
Accuracy of the localization 0.2 m
Antennas UWB antenna integrated
PHASE radio frequencies (data transfer and optional locali‐
zation)
Wireless method IEEE 802.15.4
Transmission speed 1 Mbps
Operating frequency rated value
2.40 … 2.48 GHz ISM band
Transmit power Max. 4 dBm (can be set)
Range Max. 50 m
Accuracy of the localization 1 m
Antennas 2.4 GHz antenna integrated
Bandwidth 2 MHz; data transmission on 802.15.4; channels can be set
Supply voltage, power consumption
Supply voltage 3.3 V DC (±100 mV)
Energy intake Max. 0.5 A
Permitted ambient conditions
Ambient temperature 0 to +50 °C
Design, dimensions, weights and connectors
Transponder
7.6 SIMATIC RTLS PCB OEM AC
170 System Manual, 04/2019, C79000-G8976-C577-01