7.6.3 Technical specifications
Table 7-15 Technical specifications of the transponder RTLS PCB OEM AC
6GT2700-8DF00-0AX1
Product name SIMATIC RTLS PCB OEM AC
PULSE radio frequencies (localization)
Wireless method IEEE 802.15.4-2011 UWB
Transmission speed 6.8 Mbps
Operating frequency rated value 3100 MHz … 4800 MHz
6000 MHz ... 7000 MHz
Transmit power 0.037 mW (-41.3 dBm/MHz)
Range Max. 30 m
Accuracy of the localization 0.2 m
Antennas UWB antenna integrated
PHASE radio frequencies (data transfer and optional locali‐
zation)
Wireless method IEEE 802.15.4
Transmission speed 1 Mbps
Operating frequency rated value
2.40 … 2.48 GHz ISM band
Transmit power Max. 4 dBm (can be set)
Range Max. 50 m
Accuracy of the localization 1 m
Antennas 2.4 GHz antenna integrated
Bandwidth 2 MHz; data transmission on 802.15.4; channels can be set
Supply voltage, power consumption
Supply voltage 3.3 V DC (±100 mV)
Energy intake Max. 0.5 A
Permitted ambient conditions
Ambient temperature 0 to +50 °C
Design, dimensions, weights and connectors
Transponder
7.6 SIMATIC RTLS PCB OEM AC
170 System Manual, 04/2019, C79000-G8976-C577-01