7.9.2 Installation & Operation
7.9.3 Technical specifications
Table 7-21 Technical specifications of the transponder RTLS PCB OEM PULSE
6GT2700-8AF03
Product name SIMATIC RTLS PCB OEM PULSE
PULSE radio frequencies (localization)
Wireless method IEEE 802.15.4-2011 UWB
Transmission speed 850 Kbps
Operating frequency rated value The following frequency bands are supported:
● 4000 MHz
● 6500 MHz
Transmit power 0.037 mW
Antenna Connected via antenna cable
Bandwidth 500 MHz
Range Inside maximum 90 m (typical 60 m)
Outside maximum 1000 m (typical 500 m)
Supply voltage, power consumption
Supply voltage 3.3 V DC (±100 mV)
Energy intake Max. 0.3 A
Permitted ambient conditions
Ambient temperature 0 to +50 °C
Design, dimensions, weights and connectors
PCB dimensions (L x W x H) 44 x 24 x 7.5 mm
Antenna dimensions (L x W x H) 38 x 20 x 3 mm
Weight Approx. 10 g
Method of securing PCB: 3 screws, Ø 1.7 mm
Antenna: provided by customer
7.9.4 Approvals
You can find the current EU Declaration of Conformity for these products on the Internet at
Siemens Industry Online Support.
Transponder
7.9 SIMATIC RTLS PCB OEM PULSE
192 System Manual, 04/2019, C79000-G8976-C577-01