System Manual
Table Of Contents
- SIMATIC RTLS Hardware
- Legal information - Warning notice system
- Table of contents
- 1 Introduction
- 2 Safety notices
- 3 System overview
- 4 Planning an RTLS system
- 5 Anchors
- 5.1 SIMATIC RTLS4030A
- 5.2 SIMATIC RTLS4330A
- 5.3 SIMATIC RTLS4420A
- 5.4 SIMATIC RTLS4430A
- 6 Gateways
- 6.1 SIMATIC RTLS4030G
- 6.2 SIMATIC RTLS4330G
- 6.3 SIMATIC RTLS4420G
- 6.4 SIMATIC RTLS4430G
- 7 Transponder
- 7.1 SIMATIC RTLS4030T
- 7.2 SIMATIC RTLS4060T
- 7.3 SIMATIC RTLS4083T
- 7.4 SIMATIC RTLS4084T
- 7.5 SIMATIC RTLS4460T
- 7.6 SIMATIC RTLS PCB OEM AC
- 7.7 SIMATIC RTLS PCB OEM AX
- 7.8 SIMATIC RTLS PCB OEM CHIRP
- 7.9 SIMATIC RTLS PCB OEM PULSE
5.2.1.5 Dimension drawing
3:5
5$',2
6(59(5
6,0$7,&
57/6$
Figure 5-3 Dimension drawing SIMATIC RTLS4330A - All dimensions specified in millimeters
5.2.1.6 Troubleshooting
If a fault occurs, inspect the device for the following errors and take appropriate measures. If
there are other undefined errors, please contact Siemens Support (
https://
support.industry.siemens.com/cs/start?lc=en-US).
Error detection Cause of the error Troubleshooting
Device does not respond, all LEDs are
off
The device is not connected or the pow‐
er supply unit is not switched on.
Check the supply voltage of the device.
The red LED (RUN) flashes once per
second.
Undervoltage on the device Check the supply voltage of the device.
The yellow LED (RADIO) is off. Device is not connected to the Locating
Manager.
Switch on Locating Manager.
The blue LED (SERVER) is off. Device has no network connection
(LAN)
Check local network,
Check firewall
The blue LED (SERVER) flashes. Device is not connected to the Locating
Manager.
Activate Locating Manager
Anchors
5.2 SIMATIC RTLS4330A
System Manual, 04/2019, C79000-G8976-C577-01 35