System Manual
Table Of Contents
- SIMATIC RTLS Hardware
- Legal information - Warning notice system
- Table of contents
- 1 Introduction
- 2 Safety notices
- 3 System overview
- 4 Planning an RTLS system
- 5 Anchors
- 5.1 SIMATIC RTLS4030A
- 5.2 SIMATIC RTLS4330A
- 5.3 SIMATIC RTLS4420A
- 5.4 SIMATIC RTLS4430A
- 6 Gateways
- 6.1 SIMATIC RTLS4030G
- 6.2 SIMATIC RTLS4330G
- 6.3 SIMATIC RTLS4420G
- 6.4 SIMATIC RTLS4430G
- 7 Transponder
- 7.1 SIMATIC RTLS4030T
- 7.2 SIMATIC RTLS4060T
- 7.3 SIMATIC RTLS4083T
- 7.4 SIMATIC RTLS4084T
- 7.5 SIMATIC RTLS4460T
- 7.6 SIMATIC RTLS PCB OEM AC
- 7.7 SIMATIC RTLS PCB OEM AX
- 7.8 SIMATIC RTLS PCB OEM CHIRP
- 7.9 SIMATIC RTLS PCB OEM PULSE
Installation with support - Corner installation
Follow the steps below to mount the device to a corner:
1. Use the corner support as template and draw the bore holes on the corner.
2. Drill the holes with a suitable device.
3. Insert the matching anchors in the holes. (Anchors are not supplied with the device.)
4. Mount the corner support to the corner.
5. Mount the device to the corner support using the screws (M4). (Screws are not supplied with
the device.)
Installation with support - Mast mounting
Follow the steps below to mount the device to a mast:
1. Use the mast mount as template and draw the bore holes on the mast.
2. Drill the holes with a suitable device.
3. Insert the matching anchors in the holes. (Anchors are not supplied with the device.)
4. Install the mast mount to the mast.
5. Install the device to the mast mount using the screws (M4). (Screws are not supplied with
the device.)
Note
If drilling is not possible, you can also fasten the mast mount to the mast with cable ties, for
example.
5.2.2.3 Operation
The device is not suitable for operation in hazardous areas.
Operation of the system to EN 60950-1 is only safe when the housing cover is installed (cooling,
fire protection, interference suppression).
In case of emergencies (e.g. when the enclosure is damaged, when liquids or foreign objects
are entering the device), the device must be disconnected from the power supply and
maintenance must be contacted immediately.
An anchor is ready for operation when the upper green LED lights up permanently. The other
two LEDs play no role in operational readiness.
5.2.2.4 Cleaning and maintenance
The device may only be opened by suitably trained and qualified personnel. Only authorized
dealers are permitted to repair the device.
Unauthorized opening of and improper repairs to the device may cause substantial risks to the
user. As soon as the device was opened without permission, warranty and liability of the
Siemens AG are rendered null and void.
Anchors
5.2 SIMATIC RTLS4330A
System Manual, 04/2019, C79000-G8976-C577-01 39