5.4.3 Technical specifications
Table 5-12 Technical specifications of the anchor RTLS4430A
6GT2701-5CA02
6GT2701-5CA02-0AX0
Product name SIMATIC RTLS4430A
Wireless frequencies
Wireless method IEEE 802.15.4a
Transmission speed 1 Mbps
Operating frequency 2400 ... 2480 MHz
Operating frequency rated value 2.45 GHz ISM band
Transmit power 0.00025 ... 100 mW
Range Max. 1000 m
Accuracy of the localization 1.5 m
Antennas Built-in 2.4 GHz antenna
Supply voltage, power consumption
Supply voltage 8 ... 30 V DC
Rated voltage 24 V DC
Power consumption Max. 15 W
Current consumption 0.63 A
Permitted ambient conditions
Ambient temperature -40 to +60 °C
Design, dimensions, weights, connectors
Dimensions (L x W x H) 180 x 180 x 48 mm
Weight Approx. 650 g
Degree of protection IP65
Method of securing Fixed mounting on walls or ceilings
3 x M4 screws
Enclosure Plastic enclosure (ASA and PC)
Color Titanium gray
Power plug 3-pin plug-in connector with screw-type terminal Bulgin Buc‐
caneer® PX0412/03P
5.4.4 Approvals
You can find the current EU Declaration of Conformity for these products on the Internet at
Siemens Industry Online Support.
Anchors
5.4 SIMATIC RTLS4430A
System Manual, 04/2019, C79000-G8976-C577-01 63