6.2.1.4 LED status indicator
The operating states of the gateways are indicated by the LEDs. The states can be off
, on
and flashing .
Display Meaning
POWER LED
Lights up green when power is supplied to the device through the mains cable
POWER LED
Flashes red once per second when there is an undervoltage at the device
RADIO LED
Is off when the radio signal of the device to the RTLS localization system is inactive
RADIO LED
Flashes yellow when the radio signal of the device to the RTLS localization system
is active
LAN/SERVER LED
Lights up blue when the device is connected to the network over LAN (Ethernet)
LAN/SERVER LED
Flashes blue once per second when the device is connected to the network but
there is no connection to the RTLS localization server
LAN/SERVER LED
Is off when the device is not connected to the network
Gateways
6.2 SIMATIC RTLS4330G
System Manual, 04/2019, C79000-G8976-C577-01 87