Datasheet
Single-Phase Transformers
Safety, Isolating, Control and Mains Transformers
General data
11/6
Siemens IC 10 · 2011
11
■
Overview
4AM../4AT.. transformers
With the right transformer, the right voltage will be available at
any conditions.
Our transformers are the right choice for each application: They
work reliably, safely and worldwide under a wide range of
different conditions.
Transformers are summarized in a user-friendly manner as:
• Isolating, control and mains transformers
according to EN 61558-2-4, -2-2, -2-1 or
• Safety, control and mains transformers
according to EN 61558-2-6, -2-2, -2-1
Note:
Mains transformers with
≤
50 V on the output side are, in the case
of SIRIUS transformers, always designed as safety transformers.
Our transformers provide optimal protection through high per-
missible ambient temperatures up to 40 °C or 55 °C, a high
short-time rating in the case of control transformers, fuseless
construction and due to their safety standard "Safety inside"
EN 61558.
Connection methods
4AM../4AT.. transformers are available with screw terminals/flat
connectors.
Order No. scheme
Note:
The Order No. scheme is presented here merely for information
purposes and for better understanding of the logic behind the
order numbers.
For your orders, please use the order numbers quote in the
catalog in the Selection and ordering data.
■
Benefits
• High short-time rating of the SIRIUS transformers: lower
transformer rated power for a large number of contactors
• Suitable for "fuseless construction": The small inrush current
means that "circuit breakers for motor protection" can also be
used on the primary side
•
C
U
US
approvals for the USA and Canada: can be used
worldwide without any problems
• Comprehensive type spectrum supplied from stock: rapid
availability
■
Application
Transformers are used in industrial machines, process engineer-
ing, heating and air-conditioning equipment, etc., for supplying
control and signaling circuits, when:
• Several electromagnetic loads (e.g. contactors) have to be
controlled
• Control and signaling devices are used outside the control
cabinet
• The operational voltage for the loads differs from the available
voltage level
• Voltage matching for machines and installations with electrical
isolation or as an autotransformer
Generally our transformers are used for voltage matching of
electrical devices, e.g. in communications, medical engineering
and domestic appliances.
Screw terminals
Flat connectors
The terminals are indicated in the corresponding ta-
bles by the symbols shown on orange backgrounds.
Digit of the Order No. 1st 2nd 3rd 4th 5th 6th 7th 8th 9th 10th 11th 12th 13th 14th 15th 16th
@ @ @ @ @ @ @ – @ @ @ @ @ – @ @ @ @
Transformer product type 4 A
Product group @
Rated power @ @
Power level @
Development status @
Rated input voltage @ @
Rated output voltage @ @
Version, e.g. coil form @
Application @ @
Degree of protection @
Connection type @
Example
4 A M 4 0 4 2 – 5 A T 1 0 – 0 F A 0
IC10_11.book Seite 6 Donnerstag, 16. Dezember 2010 7:53 07
© Siemens AG 2010