Data Sheet

● Fall height, max.
0.3m; five times, in product package
Ambient temperature during operation
● min.
-40°C; = Tmin (incl. condensation/frost); start-up @ -25 °C
● max.
60°C; = Tmax; Tmax > +55 °C number of simultaneously
switched-on digital inputs 7, digital outputs 5, analog inputs 2 (no
adjacent points) with horizontal mounting position
● At cold restart, min.
-25°C
Ambient temperature during storage/transportation
● min.
-40°C
● max.
70°C
Altitude during operation relating to sea level
● Installation altitude above sea level, max.
2000m
● Ambient air temperature-barometric pressure-
altitude
Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500
m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ...
+5 000 m); above 2 000 m max. 132 V AC
Relative humidity
● With condensation, tested in accordance with
IEC 60068-2-38, max.
100%; RH incl. condensation/frost (no commissioning under
condensation conditions)
Vibrations
● Vibration resistance during operation acc. to
IEC 60068-2-6
2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail
● Operation, tested according to IEC 60068-2-6
Yes
Shock testing
● tested according to IEC 60068-2-27
Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak
value), duration 11 ms
Resistance
Coolants and lubricants
— Resistant to commercially available
coolants and lubricants
Yes; Incl. diesel and oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according
to EN 60721-3-3
Yes; Class 3B2 mold, fungus and dry rot spores (with the
exception of fauna); Class 3B3 on request
— to chemically active substances according
to EN 60721-3-3
Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-
52 (severity degree 3); *
— to mechanically active substances
according to EN 60721-3-3
Yes; Class 3S4 incl. sand, dust, *
Use on ships/at sea
— to biologically active substances according
to EN 60721-3-6
Yes; Class 6B2 mold and fungal spores (excluding fauna); Class
6B3 on request
— to chemically active substances according
to EN 60721-3-6
Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-
52 (severity degree 3); *
— to mechanically active substances
according to EN 60721-3-6
Yes; Class 6S3 incl. sand, dust; *
6AG1214-1HG40-5XB0 Subject to change without notice
Page 7/
8
09/16/2019 © Copyright Siemens