Data Sheet
● EN 50155
Yes; Sections 4, 5 and 12; no further agreements apply; T1,
Category 1, Class A/B, EN 50155:2007
Ambient conditions
Ambient temperature during operation
● min.
-25°C; = Tmin
● max.
60°C; = Tmax; the rated temperature range of -25 ... +55 °C (T1)
applies for the use on railway vehicles according to EN50155
Ambient temperature during storage/transportation
● min.
-40°C
● max.
70°C
Altitude during operation relating to sea level
● Installation altitude above sea level, max.
5000m
● Ambient air temperature-barometric pressure-
altitude
Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) //
Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500
m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5
000 m)
Relative humidity
● With condensation, tested in accordance with
IEC 60068-2-38, max.
100%; RH incl. condensation/frost (no commissioning under
condensation conditions)
Resistance
Use in stationary industrial systems
— to biologically active substances according
to EN 60721-3-3
Yes; Class 3B2 mold, fungus and dry rot spores (with the
exception of fauna); Class 3B3 on request
— to chemically active substances according
to EN 60721-3-3
Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-
52 (severity degree 3); *
— to mechanically active substances
according to EN 60721-3-3
Yes; Class 3S4 incl. sand, dust, *
Use on land craft, rail vehicles and special-purpose vehicles
— to biologically active substances according
to EN 60721-3-5
Yes; Class 5B2 mold, fungus and dry rot spores (with the
exception of fauna); Class 5B3 on request
— to chemically active substances according
to EN 60721-3-5
Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 50155
(ST2); *
— to mechanically active substances
according to EN 60721-3-5
Yes; Class 5S3 incl. sand, dust; *
Remark
— Note regarding classification of
environmental conditions acc. to EN 60721,
EN 60654-4 and ANSI/ISA-71.04
* The supplied plug covers must remain in place over the unused
interfaces during operation!
Configuration
Configuration software
● STEP 7
Yes; STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or
higher with HSP 203
● STEP 7 Lite
No
Programming
6AG1312-5BF04-2AY0 Subject to change without notice
Page 11/
12
09/14/2019 © Copyright Siemens