Data Sheet
Reverse polarity protection Yes
Input current
Current consumption, max. 150mA
Power
Power available from the backplane bus 0.8W
Power loss
Power loss, typ. 5W
Digital outputs
Type of digital output Relays
Number of digital outputs 16
Current-sinking Yes
Current-sourcing Yes
Digital outputs, parameterizable Yes
Short-circuit protection No
Controlling a digital input Yes
Size of motor starters according to NEMA, max. 5
Switching capacity of the outputs
● on lamp load, max.
50 W (230 V AC), 5 W (24 V DC)
Output current
● for signal "1" rated value
2A
● for signal "1" permissible range, min.
10mA; 10 V
● for signal "1" permissible range, max.
2A; thermal continuous current
● for signal "0" residual current, max.
0A
Parallel switching of two outputs
● for logic links
Yes
● for uprating
No
● for redundant control of a load
Yes
Switching frequency
● with resistive load, max.
1Hz
● with inductive load, max.
0.5Hz
● on lamp load, max.
1Hz
Total current of the outputs
● Current per channel, max.
2A; see additional description in the manual
● Current per group, max.
2A; see additional description in the manual
● Current per module, max.
32A; see additional description in the manual
Relay outputs
● Number of relay outputs
16
● Rated supply voltage of relay coil L+ (DC)
24V
● Current consumption of relays (coil current of
all relays), max.
150mA
● external protection for relay outputs
Miniature circuit breaker B10 / B16