ET 200 - characteristics 17
Configurator (selection tool)
Just a mouse click away from a tailor-made I/O station
With the Configurator, you get first class support with assem-
bling your overall automation system (SIMATIC S7, ET 200 sta-
tion). The software tool guides you comfortably, easily and
conveniently through the configuration and creates automat-
ic ordering lists for you including accessories. It also supports
you with compliance with limitations, for example, for load
currents, slot rules or parameters.
The configuration generated can be imported easily into
STEP 7. This reduces the engineering overhead and avoids
double entries. The software tool is structured clearly:
Six configuration views make working easy and convenient:
General: General station data as well as a graphical presen-
tation of the configured station
Module selection: Guided selection of modules by means
of module suggestions
Limits: Display of station size, weight, number of
modules, load voltage, parameters, etc.
Accessories: Guided selection of the required accessories
(module-specific or station-wide)
Potential distribution: Graphical presentation of the
potentials within a station
Parts list: Automatic generation of a transparent parts list
makes ordering easier
You can find the field-proven ET 200S, ET 200M, ET 200iSP,
ET 200pro, ET 200ecoPN and ET 200eco devices in the
SIMATIC Selection Tool. You can configure the new ET 200SP
in the TIA Selection Tool.
Configuration made easy with the TIA Selection Tool
Standards and approvals
CAx data
"CAx data"
(product data, graphics, manuals) are available for our ET 200
systems as free downloads via the CAx online shopping cart:
www.siemens.com/cax
Configuration engineers, electrical planning engineers, and
commissioning engineers with CAE systems such as EPLAN
Electric P8, can use such CAx data for quick and easy creation
of, for example, electrical circuit diagrams, installation dia-
grams, and parts lists, as well as for wiring and servicing the
control cabinet. In this way, the best possible support is pro-
vided for the customer's project - from product selection,
through electronic
CAx data provision, right up to generating CAE/CAD documen-
tation.
You can find the Configurator on the Internet at:
www.siemens.com/et200
www.siemens.com/tia-selection-tool
or in the Industry Mall and also in the Catalog CA01 on DVD
Standards and approvals
PROFIBUS EN 50 170, Volume 2
PROFINET IEC 61158
IEC 1131 IEC 1131, Part 2
UL Acc. to UL508 standard, File No.
E 116536/E 75310 (AC modules)
CSA Acc. to standard C22.2 No. 142.
File No. LR 48323/LR 44226
(AC modules)
cULus
(for hazardous locations)
Acc. to UL 508 standard
File no. E 116536
acc. to hazardous locations
UL 1604
File no. E 222109
acc. to CSA C22.2 standard
No. 142
FM Standard Class No. 3611,
Class I Div. 2, Group A, B, C, D
Class I, Zone 2, Group IIC
(without motor starter)
Shipbuilding American Bureau of Shipping
Bureau Veritas
Det Norske Veritas
Germanischer Lloyd
Lloyds Register of Shipping
Nippon Kaiji Kyokai
Ex approval Cat. 3
(for Zone 2 acc. to ATEX-100a)
EN 50 021
ISA ISA-S71.04
Severity Level G1, G2, G3
(for ET 200S, ET 200M, ET 200iSP)
Safety IEC 62061 up to SIL3,
EN ISO 13849-1 up to PLe, as well as
EN 954-1 up to Cat. 4
Corrosive gas resistance (in
SIPLUS extreme version)
EN 60721-3-3 for classes 3C4, 3B2
and 3S4
Salt fog test (in SIPLUS extreme
version)
According to EN 60068-2-52
SIMATIC_ET200_ENGLISCH.book Seite 17 Montag, 26. November 2012 10:02 10