Brochure

Stronger in performance
Communication with PROFINET and PROFIBUS
High-performance automation solutions with distributed I/Os are only made possible
through industrial communication. PROFINET represents the powerful Ethernet standard
with minimum cycle times for automation. The isochronous mode of the SIMATIC ET
200SP backplane bus supports low-jitter data transfer – and thus allows for maximum
precision. The interface module of SIMATIC ET 200SP is also available for connection
to PROFIBUS.
Hot swapping
SIMATIC ET 200SP also facilitates hot swapping with multiple modules (multi hot
swapping). This means that multiple modules can be simultaneously removed and
replaced during ongoing operation. As a result, only affected modules fail instead of
the entire station. This ensures reduced downtimes and increased productivity as the
unaffected system components of SIMATIC ET 200SP remain in operation.
Safety Integrated
SIMATIC ET 200SP supports safety-related communication. The safety DI and DO modules
are equivalent in size to the standard modules. Their functional safety is certified in accor-
dance with EN 61508. They are rated for safety-related applications up to SIL3 in accor-
dance with EN 62061 and PL e in accordance with ISO 13849. As a special highlight of
SIMATIC ET 200SP fail-safe modules, the fail-safe addresses are assigned via engineering
during commissioning. This simplifies the setup process and saves time.
New highlights
SIMATIC ET 200SP Controllers: CPU 1510SP-1PN and CPU 1512SP-1PN
SIMATIC ET 200SP CPUs with PROFINET feature the same functionalities as the S7-1511 /
S7-1513 CPUs, e.g. integrated trace function, web server and fully symbolic programming.
These CPUs come with 3 integrated Ethernet ports, 2 Ethernet connection ports can be
flexibly selected by means of bus adapters as a cost saving feature. These CPUs can also
be configured as interface modules with the iDevice functionality.
PRONETA
PRONETA ensures eased commissioning and configuration of your PROFINET network.
Your network’s topology is automatically read in. You can either change the address
parameters of your SIMATIC ET 200SP station manually or use the parameters of a
template. I/O modules can be parameterized, controlled and monitored with the help
of PRONETA. The test results are logged in a clearly structured protocol.
www.siemens.com/proneta
TIA Selection Tool
The TIA Selection Tool offers assistants for the selection of desired devices and networks.
Moreover, it provides configurators for the selection of modules and accessories as well
as for the verification of correct operability. The TIA Selection Tool generates a complete
order list on the basis of your product selection or product configuration.
www.siemens.com/tia-selection-tool
7