Brochure

SIMATIC ET 200S24
Interface modules for bus connection
ET 200S is connected to the bus system via the interface mod-
ule – either to the field-proven PROFIBUS or to PROFINET, the
open Industrial Ethernet standard.
Various interface modules can be chosen, which all provide
for channel-specific diagnostics:
Interface modules without CPU functionality
IM 151-1 BASIC
IM 151-1 COMPACT
IM 151-1
5)
Standard/
Standard FO
IM 151-1
5)
High Feature (HF)
IM 151-3 PN
5)
IM 151-3 PN HF
5)
IM 151-3 PN FO
IM 151-3 PN HS
PROFIBUS Copper Copper/FOC
1)
Copper
- - -
PROFINET
-
- -
Copper Copper/FOC
1)
Copper
6)
2-port switch
4)
-
- -
n n n
Number of mod-
ules
12 63 63 63 63 32
Station width 2 m 1 m/2 m 2 m 2 m 2 m 0.5 m
Fail-safety
- - n - n -
Isochronous
mode
- - n - - n
6)
PROFIenergy
- - - - n
/
- -
Shared device
- - - n n n
MRP
- - - n n
/
-
-
Electronic
rating plate
2)
- n n n n n
Firmware update
-
Bus
n
Bus/Micro
Memory Card
Bus/Micro
Memory Card
Bus/Micro
Memory Card
Order No. group
6ES7 151-
1CA. 1AA. / 1AB. 1BA. 3AA. 3BA. 3BA6-.
Interface modules with CPU functionality
3)
IM 151-7
CPU/
CPU FO
5)
IM 151-7
5)
F-CPU
IM 151-8
5)
PN/DP CPU
IM 151-8F
5)
PN/DP CPU
PROFIBUS Copper/FOC
1)
Copper
n
3)
n
3)
PROFINET
- -
Copper Copper
2-port switch
4)
- -
n
7)
n
7)
Number of mod-
ules
63 63 63 63
Station width 2 m 2 m 2 m 2 m
Fail-safety
-
n
-
n
Isochronous
mode
- - - -
PROFIenergy
- -
n -
I-Device
- -
n n
Shared device
- -
n n
MRP
- -
n n
Electronic
rating plate
2)
- -
n n
Firmware update Micro
Memory Card
Micro
Memory Card
Bus, Micro
Memory Card
Bus, Micro
Memory Card
Order No. group
6ES7 151-
7AA. / 7AB. 7FA. 8AB. 8FB.
1)
Plastic, polymer-cladded fiber (PCF)
2)
The electronic rating plate contains identification data saved
in a module, e.g. order number, product version, installation
date, plant identification, which unequivocally identify the
module and are available online, to simplify troubleshooting,
for example.
3)
Additional PROFIBUS line with master module
6ES7 138-4HA.
4)
The integral 2-port switch of the IM 151-3 now also easily
permits a linear structure in addition to the star topology.
5)
Also available as a SIPLUS component for extended
temperature range -40 °C … +70 °C and corrosive atmo-
sphere/condensation
(for details, see
www.siemens.com/siplus-extreme
).
6)
Available with SIMOTION controller as of V4.1 SP1 and
PROFINET with IRT.
7)
3 port-switch
Interface module IM 151-3 PN HF
for PROFINET with standard cable
Interface module IM 151-3 PN FO
with fiber optic cable
n
can be used / available
- cannot be used / not available
SIMATIC_ET200_ENGLISCH.book Seite 24 Montag, 26. November 2012 10:02 10
© Siemens AG 2012