Data Sheet

Time difference in system when synchronizing via
● Ethernet, max.
10ms; Via NTP
● MPI, max.
200ms
Interfaces
Number of RS 485 interfaces 2
Number of other interfaces 2; Fiber-optic interface
1. Interface
Interface type Integrated
Physics RS 485 / PROFIBUS + MPI
Isolated Yes
Power supply to interface (15 to 30 V DC), max. 150mA
Number of connection resources MPI: 32, DP: 16
Protocols
● MPI
Yes
● PROFIBUS DP master
Yes
● PROFIBUS DP slave
No
MPI
● Number of connections
32; If a diagnostics repeater is used on the line, the number of
connection resources on the line is reduced by 1
● Transmission rate, max.
12Mbit/s
Services
— PG/OP communication
Yes
— Routing
Yes
— Global data communication
No
— S7 basic communication
No
— S7 communication
Yes
— S7 communication, as client
Yes
— S7 communication, as server
Yes
PROFIBUS DP master
● Number of connections, max.
16; If a diagnostics repeater is used on the line, the number of
connection resources on the line is reduced by 1
● Transmission rate, max.
12Mbit/s
● Number of DP slaves, max.
32
Services
— PG/OP communication
Yes
— Routing
Yes
— Global data communication
No
— S7 basic communication
No
— S7 communication
Yes
— S7 communication, as client
Yes
— S7 communication, as server
Yes
6ES7412-5HK06-0AB0 Subject to change without notice
Page 6/
13