Data sheet 6ES7414-3XM07-0AB0 SIMATIC S7-400, CPU 414-3 Central processing unit with: Work memory 4 MB, (2 MB code, 2 MB data), 1st interface MPI/DP 12 Mbit/s, 2nd interface PROFIBUS DP, 3rd interface plug-in IFM module General information Product type designation CPU 414-3 HW functional status 01 Firmware version V7.0 Engineering with ● Programming package STEP 7 V5.
Power loss Power loss, typ. 5.5 W Power loss, max. 6.5 W Memory Type of memory RAM Work memory ● integrated 4 Mbyte ● integrated (for program) 2 Mbyte ● integrated (for data) 2 Mbyte ● expandable No Load memory ● expandable FEPROM Yes; with Memory Card (FLASH) ● expandable FEPROM, max. 64 Mbyte ● integrated RAM, max. 512 kbyte ● expandable RAM Yes; with Memory Card (RAM) ● expandable RAM, max.
● Size, max. 64 kbyte ● Number, max. see instruction list ● Size, max.
Time range — lower limit 10 ms — upper limit 9 990 s IEC timer ● present Yes ● Type SFB ● Number Unlimited (limited only by RAM capacity) Data areas and their retentivity retentive data area in total Total working and load memory (with backup battery) Flag ● Number, max. 8 kbyte; Size of bit memory address area ● Retentivity available Yes ● Retentivity preset MB 0 to MB 15 ● Number of clock memories 8; in 1 memory byte Local data ● adjustable, max.
Hardware configuration Number of expansion units, max. 21 connectable OPs 63 Multicomputing Yes; 4 CPUs max. (with UR1 or UR2) Interface modules ● Number of connectable IMs (total), max. 6 ● Number of connectable IM 460s, max. 6 ● Number of connectable IM 463s, max. 4; IM 463-2 Number of DP masters ● integrated 2 ● via CP 10; CP 443-5 Extended ● via IM 467 4 ● Mixed mode IM + CP permitted No; IM 467 cannot be used jointly with CP 443-5 Ext.
Clock synchronization ● supported Yes ● to MPI, master Yes ● to MPI, slave Yes ● to DP, master Yes ● to DP, slave Yes ● in AS, master Yes ● in AS, slave Yes ● on Ethernet via NTP No; Via CP ● to IF 964 DP Yes Time difference in system when synchronizing via ● MPI, max.
● Number of connections, max. 16; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 ● Transmission rate, max. 12 Mbit/s ● Number of DP slaves, max.
— S7 communication Yes — S7 communication, as client Yes — S7 communication, as server Yes — Direct data exchange (slave-to-slave communication) No — DPV1 No Transfer memory — Inputs 244 byte — Outputs 244 byte 2. Interface Interface type Integrated Physics RS 485 / PROFIBUS Isolated Yes Power supply to interface (15 to 30 V DC), max.
— User data per DP slave, max. 244 byte — Inputs, max. 244 byte — Outputs, max. 244 byte — Slots, max. 244 — per slot, max. 128 byte PROFIBUS DP slave ● Number of connections 16 ● GSD file http://support.automation.siemens.com/WW/view/en/113652 ● Transmission rate, max. 12 Mbit/s ● Address area, max. 32 ● User data per address area, max. 32 byte — of which consistent, max.
— S7 communication, as server Yes — Equidistance Yes — Isochronous mode Yes — SYNC/FREEZE Yes — Activation/deactivation of DP slaves Yes — Direct data exchange (slave-to-slave communication) Yes — DPV0 Yes — DPV1 Yes Address area — Inputs, max. 6 kbyte — Outputs, max. 6 kbyte User data per DP slave — User data per DP slave, max. 244 byte — Inputs, max. 244 byte — Outputs, max. 244 byte — Slots, max. 244 — per slot, max.
Open IE communication ● ISO-on-TCP (RFC1006) — Data length, max. Via CP 443-1 and loadable FB 1452 bytes via CP 443-1 Adv. Web server ● supported No Isochronous mode Isochronous operation (application synchronized up to terminal) Yes; For PROFIBUS only Equidistance Yes Number of DP masters with isochronous mode 3 User data per isochronous slave, max. 244 byte shortest clock pulse 1 ms; 0.5 ms without use of SFC 126, 127 max.
● Number of simultaneous AG-SEND/AG-RECV orders per CPU, max. 24/24 Standard communication (FMS) ● supported Yes; Via CP and loadable FB Number of connections ● overall 64 ● usable for PG communication 63 — reserved for PG communication 1 — adjustable for PG communication, max. 0 ● usable for OP communication 63 — reserved for OP communication 1 — adjustable for OP communication, max.
● in 1000 ms grid, max. 512 Number of additional values ● with 100 ms grid, max. 1 ● with 500, 1000 ms grid, max. 10 Test commissioning functions Status block Yes; Up to 16 simultaneously Single step Yes Number of breakpoints 16 Status/control ● Status/control variable Yes; Up to 16 variable tables ● Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters ● Number of variables, max.
● STEP 7 Yes Programming ● Command set see instruction list ● Nesting levels 7 ● Access to consistent data in process image Yes ● System functions (SFC) see instruction list ● System function blocks (SFB) see instruction list Programming language — LAD Yes — FBD Yes — STL Yes — SCL Yes — CFC Yes — GRAPH Yes — HiGraph® Yes Number of simultaneously active SFCs — DPSYC_FR 2; SFC 11; per interface — D_ACT_DP 8; SFC 12; per interface — RD_REC 8; SFC 59; per interface — WR_REC 8;
last modified: 6ES7414-3XM07-0AB0 Page 15/15 09/12/2019 09/13/2019 Subject to change without notice © Copyright Siemens