Data Sheet

● as server
Yes
● as client
Yes
● User data per job, max.
64kbyte
● User data per job (of which consistent), max.
462byte; 1 variable
S5 compatible communication
● supported
Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or
443-5
● User data per job, max.
8kbyte
● User data per job (of which consistent), max.
240byte
● Number of simultaneous AG-SEND/AG-RECV
orders per CPU, max.
64/64
Standard communication (FMS)
● supported
Yes; Via CP and loadable FB
PROFINET CBA (at set setpoint communication load)
● Setpoint for the CPU communication load
20%
● Number of remote interconnection partners
32
● Number of functions, master/slave
150
● Total of all master/slave connections
6000
● Data length of all incoming connections
master/slave, max.
65000byte
● Data length of all outgoing connections
master/slave, max.
65000byte
● Number of device-internal and PROFIBUS
interconnections
1000
● Data length of device-internal und PROFIBUS
interconnections, max.
16000byte
● Data length per connection, max.
2000byte
Remote interconnections with acyclic transmission
— Sampling frequency: Sampling time, min.
200ms; Depending on preset communication load, number of
interconnections and data length used
— Number of incoming interconnections
500
— Number of outgoing interconnections
500
— Data length of all incoming
interconnections, max.
16000byte
— Data length of all outgoing
interconnections, max.
16000byte
— Data length per connection, max.
2000byte
Remote interconnections with cyclic transmission
— Transmission frequency: Transmission
interval, min.
1ms; Depending on preset communication load, number of
interconnections and data length used
— Number of incoming interconnections
300
— Number of outgoing interconnections
300
6ES7416-3FS07-0AB0 Subject to change without notice
Page 13/
17
09/13/2019 © Copyright Siemens