Data sheet 6ES7672-7AC01-0YA0 SIMATIC S7-1500, Software Controller CPU 1507S Single license f. 1 install., R-SW, SW and documentation on DVD, License key on USB stick, R-SW Class A, 6 languages (de,en,it,fr,es,zh), executable in Windows 7 and Windows 10; Reference HW: SIMATIC IPC2x7E, IPC4x7E, IPC4x7D, IPC6x7D, IPC8x7D General information Product type designation CPU 1507S Software version V2.6 Engineering with ● STEP 7 TIA Portal configurable/integrated as of version V15.
● with UPS Yes; all memory areas declared retentive ● with non-volatile memory Yes; Depending on PC hardware CPU processing times for bit operations, typ. 1 ns; On IPC427E, Intel Xeon processor for word operations, typ. 2 ns; On IPC427E, Intel Xeon processor for fixed point arithmetic, typ. 2 ns; On IPC427E, Intel Xeon processor for floating point arithmetic, typ.
● Number Any (only limited by the main memory) Retentivity — adjustable Yes S7 times ● Number 2 048 Retentivity — adjustable Yes IEC timer ● Number Any (only limited by the main memory) Retentivity — adjustable Yes Data areas and their retentivity Retentive data area (incl. timers, counters, flags), max. 135 kbyte; On SIMATIC IPC227E, IPC277E, IPC427D, IPC477D and IPC427E, IPC477E; 35 KB on SIMATIC IPC627D, IPC677D and IPC827D Extended retentive data area (incl. timers, counters, flags), max.
● Deviation per day, max. Depending on PC hardware Operating hours counter ● Number 16 Clock synchronization ● supported Yes ● to DP, master No ● on Ethernet via NTP Yes ● on Windows clock, slave Yes Interfaces Number of interfaces 3 Number of PROFINET interfaces 2; In case of I-Device configuration, only one PROFINET interface is supported Number of PROFIBUS interfaces 1 1.
— Number of connectable IO Devices for RT, max. 256 — of which in line, max. 256 — Number of IO Devices that can be simultaneously activated/deactivated, max. 8 — IO Devices changing during operation (partner ports), supported Yes; The CPU and changing IO devices must be separated by a switch (e.g. SCALANCE X205) — Number of IO Devices per tool, max.
2. Interface Interface type Onboard PROFINET / IE interface X2 of the SIMATIC IPC, Intel Springville i210T Interface types ● Number of ports 1 ● integrated switch No ● RJ 45 (Ethernet) Yes — Transmission rate, max.
Services — Isochronous mode No — IRT No — MRP No — MRPD No — PROFIenergy Yes — Shared device Yes — Number of IO Controllers with shared device, max. 4 — Asset management record Yes 3.
Address area — Inputs, max. 8 kbyte — Outputs, max. 8 kbyte Protocols Number of connections ● Number of connections, max. 128 ● Number of connections reserved for ES/HMI/web 10 ● Number of S7 routing paths 16 SIMATIC communication ● PG/OP communication Yes ● S7 routing Yes ● S7 communication, as server Yes ● S7 communication, as client Yes ● User data per job, max. 64 kbyte; BSEND/BRCV: 64 KB; PUT/GET: 960 bytes Open IE communication ● TCP/IP — Data length, max.
— Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_Rea dList/OPC_UA_WriteList, max. 300 — Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max. 20 — Number of elements for one call of OPC_UA_MethodGetHandleList, max. 100 — Number of simultaneous calls of the client instructions per connection (except OPC_UA_ReadList,OPC_UA_WriteList,OPC_ UA_MethodCall), max.
S7 message functions Number of login stations for message functions, max. 32 Program alarms Yes Number of configurable program messages, max.
● Number of available Motion Control resources for technology objects (except cam disks) 4 800 ● Required Motion Control resources — per speed-controlled axis 40; per axis — per positioning axis 80; per axis — per synchronous axis 160; per axis — per external encoder 80; per external encoder — per output cam 20; per cam — per cam track 160; per cam track — per probe 40; per probe ● Required Extended Motion Control resources — for each cam 2 — for each set of kinematics 30 ● Positioning a
● Windows 7 Yes; Professional, Enterprise, Ultimate (32 bit and 64 bit) ● Windows Embedded Standard 7 Yes; With the delivery image of the SIMATIC PC ● Windows 8 No ● Windows Embedded Standard 8 No ● Windows 10 Yes; Windows 10 Enterprise 2016 LTSB, 64 bit, MUI on IPC2x7E, IPC4x7E, IPC6x7D and IPC8x7D Configuration Programming Programming language — LAD Yes — FBD Yes — STL Yes — SCL Yes — CFC No — GRAPH Yes Know-how protection ● User program protection/password protection Yes ● Copy pr