Data Sheet
Operating current / of the signaling contacts
● at DC / maximum
0.1A
Supply voltage, current consumption, power loss
Type of voltage / of the supply voltage DC
Supply voltage
● external
24V
● external / minimum
9.6V
● external / maximum
31.2V
Supply voltage / 1 / Rated value 12V
● Supply voltage / 1 / rated value
9.6...31.2V
● Type of voltage / 1 / of the supply voltage
DC
● Consumed current / 1 / at rated supply voltage /
maximum
0.25A
Supply voltage / 2 / Rated value 24V
● Supply voltage / 2 / rated value
9.6...31.2V
● Type of voltage / 2 / of the supply voltage
DC
● Consumed current / 2 / at rated supply voltage /
maximum
0.125A
● Power loss [W] / 2 / Rated value
3W
Product component / fusing at power supply input Yes
Fuse protection type / at input for supply voltage 2.5 A / 125 V
Power loss [W]
● at DC / at 24 V
3W
Permitted ambient conditions
Ambient temperature
● during operation
-40...+70°C
● during storage
-40...+85°C
● during transport
-40...+85°C
Relative humidity
● at 25 °C / without condensation / during
operation / maximum
95%
Protection class IP IP20
Design, dimensions and weight
Design compact
Width 60mm
Height 147mm
Depth 125mm
Net weight 0.85kg
Material / of the enclosure Polycarbonate (PC-GF10)
Mounting type
● 35 mm DIN rail mounting
Yes
● wall mounting
Yes
6GK5108-0BA00-2AC2 Subject to change without notice
Page 2/
4
08/27/2019 © Copyright Siemens