Data Sheet

Permitted ambient conditions
Ambient temperature
● during operation
-40...+85°C
● during storage
-40...+85°C
● during transport
-40...+85°C
● Note
A maximum operating temperature of +85°C is permissible for a
duration of 16 hours
Relative humidity / at 25 °C / without condensation /
during operation / maximum
95%
Protection class IP IP20
Design, dimensions and weight
Design SFP Module
Width 14mm
Height 9mm
Depth 57mm
Net weight 0.01kg
Mounting type latched
Standards, specifications, approvals
Standard
● for FM
FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone
2, Group IIC, T4
● for hazardous zone
EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA
07 ATEX 0145 X
● for safety / from CSA and UL
UL 60950-1, CSA C22.2 No. 60950-1-03
● for emitted interference
EN 61000-6-4:2007 (Class A)
● for interference immunity
EN 61000-6-2:2005
Certificate of suitability EN 61000-6-2:2005, EN 61000-6-4:2007
● CE marking
Yes
● C-Tick
Yes
● KC approval
No
Marine classification association
● Bureau Veritas (BV)
Yes
MTBF 120y
Further Information / Internet Links
Internet-Link
● to website: Selector SIMATIC NET
SELECTION TOOL
http://www.siemens.com/snst
● to website: Industrial communication
http://www.siemens.com/simatic-net
● to website: Industry Mall
https://mall.industry.siemens.com
● to website: Information and Download Center
http://www.siemens.com/industry/infocenter
● to website: Image database
http://automation.siemens.com/bilddb
● to website: CAx Download Manager
http://www.siemens.com/cax
6GK5991-1AD00-8AA0 Subject to change without notice