LOGO! functions
4.4 Special functions list - SF
LOGO!
202 Manual, 06/2014, A5E33039675
Message text function block
Symbol in LOGO!
Wiring
Description
Input En A 0 to 1 transition at input En (Enable) starts the
output of the message text.
Parameter Ack: acknowledgment of the message text
Msg Text: input of the message text
Priority: priority of the message text
Range of values: 0 to 127
Tick Type:
C-C: tick message character by character
L-L: tick message line by line
Msg. Dst: message destination (BM, TDE or Both)
Web Show: show LOGO! Basic on Web server
Line tick settings (to define whether a line ticks):
Line1 Tick
Line2 Tick
Line3 Tick
Line4 Tick
Line5 Tick
Line6 Tick
Note:
You can only edit the Text parameter of the
message from LOGO! Basic. ISO8859-1 is the only
available character set for editing text. You can edit
all other parameters, and other languages for the
Text parameter from LOGO!Soft Comfort. For
configuration details, refer to the Online Help for
LOGO!Soft Comfort.
Output Q Q remains set as long as the message text is set.
Restriction
A maximum of 50 message text blocks are available.
Functional description
When LOGO! is in RUN mode, LOGO! displays the message text that you have configured
along with its parameter values upon a 0 to 1 transition of the signal at input En.
Based on your setting for the message destination, the message text displays on the
LOGO! onboard display, the LOGO! TDE, or both.
If you use flag M27 in your circuit program, then if M27=0 (low) then LOGO! displays the
message text only if it is from the primary character set (Character Set 1). If M27=1 (high),
then LOGO! displays the message text only if it is from the secondary character set
(Character Set 2). (See the M27 flag description in topic Constants and connectors
(Page 115)).