User Manual

Technical data
A.3 Technical data: LOGO! DM8 230R and LOGO! DM16 230R
LOGO!
Manual, 06/2014, A5E33039675
295
LOGO! 230RCEo
LOGO! 230RCE
Surge current
Incandescent lamp load (25000
switching cycles) at
230/240 VAC
115/120 VAC
Max. 30 A
1000 W
500 W
Max. 30 A
1000 W
500 W
Fluorescent tubes with ballast
(25000 switching cycles)
10 x 58 W (at 230/240 VAC) 10 x 58 W (at 230/240 VAC)
Fluorescent tubes, conventionally
compensated (25000 switching
cycles)
1 x 58 W (at 230/240 VAC) 1 x 58 W (at 230/240 VAC)
Fluorescent tubes, uncompensated
(25000 switching cycles)
10 x 58 W (at 230/240 VAC) 10 x 58 W (at 230/240 VAC)
Short circuit-proof cos 1
Power protection B16, 600 A
Power protection B16, 600 A
Short circuit-proof cos 0.5 to 0.7
Power protection B16, 900 A
Power protection B16, 900 A
Derating None; across the entire
temperature range
None; across the entire
temperature range
Parallel output circuits for power
increase
Not permitted Not permitted
Protection of output relay (if
desired)
Max. 16 A, characteristic B16 Max. 16 A, characteristic B16
Switching rate
Mechanical
10 Hz
10 Hz
Ohmic load/lamp load
2 Hz
2 Hz
Inductive load
0.5 Hz
0.5 Hz
Notice: For fluorescent lamps with capacitors, you must consider the technical data of
fluorescent lamp ballasts. If the current exceeds the maximum allowed surge current,
appropriate contactor relays must switch the flourescent lamps.
The data was determined with the following devices:
Siemens fluorescent tubes 58 W VVG 5LZ 583 3-1 uncompensated.
Siemens fluorescent tubes 58 W VVG 5LZ 583 3-1 parallel compensated with 7 μF.
Siemens fluorescent tubes 58 W VVG 5LZ 501 1-1N with ballast.
A.3
Technical data: LOGO! DM8 230R and LOGO! DM16 230R
LOGO! DM8 230R
LOGO! DM16 230R
Power supply
Input voltage
115 VAC/VDC to 240 VAC/VDC
115 VAC/VDC to 240 VAC/VDC
Permissible range 85 VAC to 265 VAC
100 VDC to 253 VDC
85 VAC to 265 VAC
100 VDC to 253 VDC
Permissible mains frequency
47Hz to 63 Hz