3.5 Configuring menu access protection for LOGO!
LOGO!
Manual, 06/2014, A5E33039675
63
3.5
Configuring menu access protection for LOGO!
LOGO! provides two access levels, administrator and operator, to limit access to specific
menus in programming mode. As an administrator, you can access all menu commands;
while as an operator, some specific menu commands are not visible (see section "Overview
of LOGO! menus (Page 65)"). LOGO!'s default setting is administrator at delivery, and you
can switch to operator at any time. When switching from operator to administrator, you need
to enter a valid password ("LOGO" by default). LOGO! always saves its access level before
power-off.
Note
The access level of the LOGO! TDE is operator by default, and you can switch it to
administrato
r with the password "LOGO".
The LOGO! TDE saves its access level before power
-off if it connects to the same Base
Module after power
-on. If you connect a different Base Module to it, however, the LOGO!
TDE restores its access level to operator after power
-on.
The access level setting on the LOGO! TDE is independent of that on the Base Module.
Switching LOGO! from administrator to operator
To switch LOGO!'s access level from administrator to operator, follow these steps:
1. Move the cursor to "
" on the main menu of programming mode: Press or
2. Confirm "
": Press
OK
3. Move the cursor to "
": Press or
4. Confirm "
": Press
OK
LOGO! now switches to the access level of operator and returns to the main menu.