User Manual

Programming LOGO!
3.7 Writing and starting the circuit program
LOGO!
Manual, 06/2014, A5E33039675
71
Note
Inputs F1, F2, F3, and F4 correspond to the four function keys on the optional LOGO!
TDE.
More shift register bits (S1.1 to S4.8), blank connectors (X1 to X64) and analog flags (AM1
to AM64) are available in the 0BA8 device series.
Network digit
al inputs (NI1 to NI64), network analog inputs (NAI1 to NAI32), network digital
outputs (NQ1 to NQ64), and network analog outputs (NAQ1 to NAQ16) are available for the
0BA8 device series. LOGO! 0BA8 does not include these inputs and outputs until you
confi
gure them in a circuit program in LOGO!Soft Comfort V8.0 and download the program
to your LOGO! 0BA8 device.
After selecting I1, the display now shows as follows:
Press
OK
to confirm. You have now connected I1 to the input of the OR block.
Now you connect input I2 to the input of the OR block:
1. Move the cursor to In2: Press
or
2. Switch to editing mode: Press
OK
3. Select the digital input list: Press
or
4. Move the cursor to the input number: Press
5. Select
I2
: Press or
6. Apply I2: Press
OK
You have now connected I2 to the second input of the OR block: