Datasheet

6SL3210-5BB15-5UV1
Data sheet for SINAMICS V20
MLFB-Ordering data
Figure similar
Rated data
Ambient conditions
General tech. specifications
Input
Output
Ambient temperature
Relative humidity
Number of phases
Max. operation
Storage
Operation
Cooling
Installation altitude
Rated power (HO)
Rated voltage
Number of phases
Line voltage
Line frequency
Power factor λ
Offset factor cos φ
Efficiency η
Rated current (HO)
Pulse frequency
Output frequency
3.20 A
0.55 kW / 0.75 hp
230 V
8.00 kHz
0.95
0.98
1000 m (3281 ft)
convection cooling
Consignment no. :
Remarks :
Item no. :
Offer no. :
Order no. :
Project :
Client order no. :
1 AC
3 AC
200 ... 240 V -15 % +10 %
47 ... 63 Hz
0 ... 550 Hz
95 %
-40 ... 70 °C (-40 ... 158 °F)
-10 ... 60 °C (14 ... 140 °F)
0.72
USS, Modbus RTU
Compliance with standards CE, cULus, C-Tick (RCM), KC
EN 61800-5-1 /EN 60204-1 and EN
61800-3
Standards
Communication
Communication
CE marking
0.55 kW / 0.55 hpRated power (LO)
3.20 ARated current (LO)
150 % rated output current for 60 s, cycle time 300 s
110 % rated output current for 60 s, cycle time 300 s
Low Overload (LO)
Overload capability
High Overload (HO)
Technical data are subject to change! There may be discrepancies between calculated and rating plate values.