Datasheet

Pressure Measurement
Transmitters for basic requirements
SITRANS P200
for gauge and absolute pressure
2/6
Siemens FI 01 · 2012
2
Technical specifications
Application
Gauge and absolute pressure
measurement
Liquids, gases and vapors
Mode of operation
Measuring principle Piezo-resistive measuring cell
(ceramic diaphragm)
Measured variable Gauge and absolute pressure
Inputs
Measuring range
Gauge pressure
-Metric
- US measuring range
1 60 bar (15 … 870 psi)
15 … 1000 psi
Absolute pressure
-Metric
- US measuring range
0.6 16 bar a (10 … 232 psia)
10 … 300 psia
Output
Current signal 4 ... 20 mA
•Load (U
B
- 10 V) / 0.02 A
Auxiliary power U
B
DC 7 ... 33 V (10 ... 30 V for Ex)
Voltage signal 0 ... 10 V DC
•Load 10 kΩ
Auxiliary power U
B
12 ... 33 V DC
Power consumption < 7 mA at 10 kΩ
Characteristic curve Linear rising
Measuring accuracy
Error in measurement at limit setting
incl. hysteresis and reproducibility
Typical: 0.25 % of full-scale
value
Maximum: 0.5 % of full-scale va-
lue
Step response time T
99
<5 ms
Long-term stability
Lower range value and measuring
span
0.25 % of full-scale value/year
Influence of ambient temperature
Lower range value and measuring
span
0.25 %/10 K of full-scale value
Influence of power supply 0.005 %/V
Conditions of use
Process temperature with gasket
made of:
FPM (Standard) -15 ... +125 °C (+5 ... +257 °F)
•Neoprene -35 ... +100 °C (-31 ... +212 °F)
Perbunan -20 ... +100 °C (-4 ... +212 °F)
•EPDM -40 ... +145 °C (-40 ... +293 °F),
usable for drinking water
Ambient temperature -25 ... +85 °C (-13 ... +185 °F)
Storage temperature -50 ... +100 °C (-58 ... +212 °F)
Degree of protection (to EN 60529) IP 65 with connector per
EN 175301-803-A
IP 67 with M12 connector
IP 67 with cable
IP 67 with cable quick screw
connection
Electromagnetic compatibility acc. EN 61326-1/-2/-3
acc. NAMUR NE21, only for
ATEX versions and with a max.
measuring deviation 1 %
Design
Weight Approx. 0.090 kg (0.198 lb)
Process connections See dimension drawings
Electrical connections Connector per
EN 175301-803-A Form A with
cable inlet M16x1.5 or ½-14 NPT
or Pg 11
M12 connector
2 or 3-wire (0.5 mm
2
) cable
( ± 5.4 mm)
Cable quick screw connection
Wetted parts materials
Measuring cell AI
2
O
3
- 96 %
Process connection Stainless steel, mat. No. 1.4404
(SST 316 L)
•Gasket FPM (Standard)
•Neoprene
Perbunan
EPDM
Non-wetted parts materials
Enclosure Stainless steel, mat. No. 1.4404
(SST 316 L)
•Rack Plastic
•Cables PVC
Certificates and approvals
Classification according to pressure
equipment directive
(PED 97/23/EC)
For gases of fluid group 1 and
liquids of fluid group 1; complies
with requirements of article 3,
paragraph 3 (sound engineering
practice)
Lloyds Register of Shipping (LR) Applied
Germanischer Lloyds Register of
Shipping (GL)
Applied
American Bureau of Shipping (ABS) Applied
Bureau Veritas (BV) Applied
Det Norske Veritas (DNV) Applied
Drinking water approval (ACS) Applied
GOST Applied
Explosion protection
Intrinsic safety "i" (only with current
output)
Ex II 1/2 G Ex ia IIC T4 Ga/Gb
Ex II 1/2 D Ex ia IIIC T125 °C
Da/Db
EC type-examination certificate SEV 10 ATEX 0146
Connection to certified intrinsically-
safe resistive circuits with maxi-
mum values:
U
i
30 V DC; I
i
100 mA;
P
i
0.75 W
Effective internal inductance and
capacity for versions with plugs per
EN 175301-803-A and M12
L
i
= 0 nH; C
i
= 0 nF
FI01_2012_en_kap02.book Seite 6 Donnerstag, 17. November 2011 4:31 16
© Siemens AG 2011
© Siemens AG 2011