Power pack AC 110/230 V
WZU-AC110/230-15 *)
WZU-AC110/230-50 *)
Power pack AC 110/230 V
● Protection class
● Voltage range
● Frequency
● Maximum power consumption
● Overvoltage category II
per EN 61010-1
● Length of connecting cable
● External fusing of supply line
● Backup time in the event of power failure
II
AC 100 to 240 V
50/60 Hz
2.5 VA
CAT 2
1.5 m/5 m
Automatic cutout 6 A
≥4 h
*) The power pack has two outputs. One supplies the meters; the other an optional plug-in
GPRS module.
Power pack AC/DC 24 V
WZU-ACDC24-50
Power pack AC/DC 24 V
● Protection class
● Power supply
● Frequency
● Maximum power consumption
● Terminals
● For connecting line
● Backup time in the event of power failure
III (SELV)
AC 12...35 V or DC 12...50 V
50/60 Hz or DC
2.5 W
2x 1.0 mm²
Ø 5...6 mm
>20 minutes
Communication
Pulse module
WZU-P2
Pulse outputs
● Number of outputs per module
● Standard pulses
– Pulse value
– Pulse length
– Period duration
● Pulse for operating states
– Pulse duration for "Ready"
– Pulse duration for "Fault"
– Period duration
● Fast pulses
– Pulse length
– Max. pulse frequency
● Fast pulses
– Pulse length
– Max. pulse frequency
2
For energy, volume and tariff register
1 kWh, 10 kWh, 1 MJ, 10 MJ, 100 MJ,
0.1 m
3
, 1 m
3
per pulse
100 ms conducting
>200 ms
0.1…0.25 ms conducting
Constantly non-conducting
500 ms
If 1 pulse module is fitted
2…100 ms in increments of 1 ms
33 Hz
If 2 pulse modules are fitted
5…100 ms in increments of 5 ms
33 Hz