User Manual

42
Smart Infrastructure
CE2N5324en
2019-06-27
Modbus module
WZU-485E-MOD
Galvanic isolation
From meter:
From the RS-485 network
Yes
No
Analog module WZU-AM
Analog outputs
Number of outputs
Output variable
Max. load at current output
Max. load at voltage output
Precision
Max. cable length
Cable cross-section
Outputs short-circuit proof
Galvanic isolation from meter
External power supply
Voltage range
Power consumption
Power consumption
External fuse (not enclosed)
< AC/DC 24 V
≥ AC/DC 24 V
Breaking capacity
2
Current or voltage configurable
300 Ω
2 kΩ
≤ ±} 1% of parameterized max. value
100 m
Max. 1.5 mm
2
Yes
Yes
AC 12…30 V or DC 12…42 V
Max. 170 mA at 12 V
Max. 2 VA
Per EN 60127-2
200 mA, slow
100 mA, slow
35 A (L)
RF module, 868 MHz
WZU-RF, WZU-RF-EXT
RF interface
Transmission frequency
Transmitter power
Receive frequency
Antenna
RF protocol
Range
As per EN 13757-2/ -4
868.95 MHz
3.16…25 mW
868.30 MHz
Integrated on WZU-RF,
external on WZU-RF-EXT
OMS-/DSMR compliant data transmission
Max. 400 m/typically 30 m in buildings