Building Technologies Operating Instructions for ACS Operating and ACS Service CE1U5640en
HVAC Products 2 Processes Dec. 1, 2005
the PC. When supplied, central units carry standard code number 01.
Note: The code number must always start with a zero, e.g. 01.
• Connection (OZW771, OCI600, OCI611, OZW10, OZW111, OCI69): All possible
connections will be listed. For a direct connection, select the COM or USB port to
which the central unit was connected. For a modem connection, select the installed
modem via which the connection shall be established. The relevant preparatory
steps are described in chapter Prepare the connection to the plant.
• USB (OZW775): For a direct connection to the PC
• Modem (OZW775): For a modem connection to the PC
• Phone no. plant (OZW775, OZW771, OCI600, OCI611, OZW10, OZW111): This
is the phone no. under which the central unit can be reached via modem. For direct
connections not made via modem, there is no need to enter a phone no.. Please
ensure that you do not forget the exchange code, the area code or other parts of
the phone no.
• Return call (OZW10): When you select the return call, first the connection to the
central unit is opened. Then, the connection is cut and the central unit makes a
return call. The largest part of the telephone charges are billed in this way. For
direct connections, the return call should be disabled
• Switch box type (in preparation for OZW771, OCI600, OCI611, OZW10, and
OZW111): When you select a switch box type, several central units of the same
type can be addressed via one connection
• Switch box port (in preparation for OZW771, OCI600, OCI611, OZW10, and
OZW111): After having selected a switch box type, you can define the port to which
the central unit was connected
• Search area (OCI700 - KNX): The device list can be updated more quickly if the
search area is confined. The following settings are available:
Konnex bus system:
• Device at OCI700: Only the device connected directly to the OCI700 will be
included in the device list. If the OCI700 is connected via a bus conduit box, none
of the devices can be identified
• Line at OCI700: The devices acquired are all those that belong to the same line
as the device to which the OCI700 is connected. KNX line couplers will not be
included in the device list
• All lines: All devices of the system will be included in the device list. Note: If
access to other lines is restricted by KNX line couplers, devices from such lines
cannot be acquired
After the entries have been made, you can close the dialog by clicking the OK button.
The settings made in the dialog can be changed at any time via the "Plant" menu –
Plant properties...
For more information, refer to the following chapters:
• The first steps
• Working with connections
• Working with a plant
• Navigating through a plant
• Working with the devices
• Applications
2.5.6 Updating a device list
After the plant has been created and the connection to the plant has been
established, the information about the devices containd in the plant must be
transferred to the PC. If this has not yet been done after creating a plant or if, in the
meantime, the plant has been changed, proceed as follows:
Updating a device list