AlgoRex EP7F-SR1 Release Notes for Tool Coordinators Building Technologies Fire Safety & Security Prducts
Liefermöglichkeiten und technische Änderungen vorbehalten. Data and design subject to change without notice. / Supply subject to availability. Sous réserve de modifications techniques et de la disponibilité. © 2011 Copyright by Siemens Building Technologies AG Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor.
1 About this document ..............................................................................5 2 2.1 2.2 2.2.1 Introduction .............................................................................................6 Purpose of the document..........................................................................6 General focus on EP7F-SR1 ....................................................................6 Completion of AlgoRex ..................................................................
5.6 5.6.1 5.6.2 5.7 5.7.1 5.7.2 Repaired bugs.........................................................................................15 Short cuts ................................................................................................15 Upload from a K3M111 line card ............................................................15 Restrictions and known bugs ..................................................................16 16bit characters not fully supported in path and directory names ........
About this document 1 About this document Modification index Version 007428_b_en_-007428_a_en_-- Date May 2011 August 2003 Brief description Information about Embedded SW 736 Initial version Related documents Reference [1] [2] [3] Document no 6824 5946 4768 Content Operating platform for Tools Visualizer to terminal CT11 TC documentation EP7F, Toolset customizing 5 Siemens Building Technologies 007428_b_en_-- Fire Safety & Security Products 05.
Introduction 2 Introduction 2.1 Purpose of the document The document describes the differences between EP7F Update 1 and EP7F-SR1. It is intended for Tool Coordinators who need to known what is new and/or different in EP7F-SR1. 2.2 General focus on EP7F-SR1 AlgoRex EP7F-SR1 has been done manly for the two countries Israel and Denmark. Also some of the known bugs were fixed. See page 8. 2.2.1 Completion of AlgoRex CT11 Visualizer – Supports Microsoft Windows NT 4.
Supported operating systems 3 Supported operating systems Operating system Microsoft Windows NT 4.0 Microsoft Windows 2000 Microsoft Windows XP Remark With service pack 6 installed. Restrictions apply for countries with non Latin character sets. With service pack 2 installed - See related document [1] 4 Versions and compatibility 4.1 AlgoWorks setup version The current AlgoWorks setup version EP7F-SR1 is V1.35.0-000. It is a full setup. Older AlgoWorks programs must be uninstalled before.
Versions and compatibility FLASH variants Station type CC1142 CC1143 CI1142 CT1142 CI1143-T1 CI1143-TE CI1143-TL CI1143-T5 CT1143-T1 CT1143-TE CT1143-TL CT1143-T5 CA1142 CA1143-T1 CA1143-TE CA1143-TL CA1143-T5 Name Control unit modular Control unit modular with extended RAM Control unit compact Control terminal Control unit compact (China, simplified) with extended RAM Control unit compact (China, traditional) with extended RAM Control unit compact (Korea) with extended RAM Control unit compact (Thailand)
Versions and compatibility 4.4 Repaired bugs in Embedded-SW 736 4.4.1 Time channels Bug description The programming of the time channels did not work correctly. 4.4.2 Bug corrected in Embedded SW 736 Soft keys on quiescent display Bug description Sometimes the soft keys provide functions, which were not corresponding with the current situation 4.4.3 Bug corrected in Embedded SW 736 Time marks on the panel Bug description The time marks were not supported on the panel. 4.4.
Versions and compatibility 4.5 Restrictions and known bugs in Embedded-SW 736 4.5.1 Supervision of emergency lines (degrade path) Bug description If the I-Bus is blocked via switch S4-10 on the E3X101 the signals for the emergency line supervision are also disabled and therefore a fault message 'degrade path fire alarm' is displayed for each station which does not detect the supervision pulses anymore. 4.5.
Versions and compatibility 4.5.6 Overlapping remote transmission references Bug description If the configuration contains any wrong device remote ID (structure number or field number) no fault message will be generated. Work around: Use the consistency check provided by AlgoWorks 4.5.7 Australian functionality The specific Australian functionality is not fully supported with the version EP7FSR1. 4.5.
AlgoWorks Software Toolset 5 AlgoWorks Software Toolset AlgoWorks EP7F now runs on Microsoft Windows NT4, Win2000 and WinXP See related document [1]. 5.1 Global information 5.1.1 Multi user possibility on one PC With EP7F Update1 it was only possible to have multi user possibilities if each user could carry out the AlgoWorks setup. Now in EP7F-SR1 it is not necessary anymore. To overtake all necessary settings one can use the Activator. It overtakes all settings without having the setup possibility.
AlgoWorks Software Toolset 5.3 Site Management 5.3.1 General Sub-windows The AlgoWorks SIM program is divided into different sub-windows, non of them can be moved, only resize or hidden is possible. Saving of column width in the tree editors All column width will be saved when closing the windows 5.3.2 New function Reorder Hebrew Customer texts This function is made for sites with Hebrew text. See online help for more information. 5.3.
AlgoWorks Software Toolset 5.4 Station Management 5.4.1 General Sub-windows The AlgoWorks SAM program is divided into different sub-windows, none of them can be moved, only resize is possible. Saving of column in the tree editors All column width will be saved when closing the windows. 5.4.2 New function Save Configuration Data As ... The menu item allows exporting the station data in a CSV format, which can be imported with another program. (E.g. Microsoft Excel) 5.4.
AlgoWorks Software Toolset 5.5 HTML Help 5.5.1 SIM-Help New or changed help topics Topic file name GEN_Welcome_to_Site_Management.htm GEN_Help_Release_Notes.htm SIM0_Menu_tools.htm SIM0_Site_function_Reorder_Hebrew_Text.htm Description New version number New version number Added text Completely new See the compiled CHM-file with the flash icon for more details. 5.5.2 SAM-Help New or changed help topics Topic file name GEN_Welcome_to_Station_Management.htm GEN_Help_Release_notes.
AlgoWorks Software Toolset 5.7 Restrictions and known bugs 5.7.1 16bit characters not fully supported in path and directory names Bug description 16bit characters must not be used in path and directory names of the AlgoWorks installation. Otherwise, conversion of EP4 (or older) sites to EP7F is not possible. Therefore, in Asian countries that are using 16bit character sets, AlgoWorks must be installed in a separate path using 8bit characters only! 5.7.
New BDV J0_114x_730_10 6 New BDV J0_114x_730_10 6.1 General The EP7F-SR1 includes two new BDV's, which are J0_1140_730_10 and J0_1145_730_10. The major changes are – – – – 6.1.1 New / chanced customer texts Changed station templates New ADD definitions Additional / changed help information New / changed customer text New customer text 22959 "Area: " Changed customer text 4453 "No connection to CA/Visualizer" 6.1.
CT11 Visualizer Customizing 6.1.4 BDV-Help New or changed help topics Topic file name FLD0_4324.html FLD0_1800.html FLD0_1600.html FLD0_1348.html FLD0_1313.html BAI0_Standard_Text_Help.
Update procedures 8 Update procedures 8.1 AlgoWorks 8.1.1 Overview The AlgoWorks setup 1.35.0-000 is a full setup. Therefore the old setup has to be uninstalled. Different situations The customizing process is in progress The customizing process was NOT started yet 8.1.2 See chapter 8.1.2 on page 19 See chapter 8.1.
Update procedures – Choose a new country code during the installation If you do not use a new country code, the directory that corresponds to the old country code (e.g. …/AW1_3/B0_00_CFG) will be overwritten and all adaptation are gone. You have to start at the beginning again. A new directory (which corresponds to the prompted country code, E.g. B0_01) will be created during the installation. Explorer view This directory was new created. This directory was overwritten.
Update procedures Procedure to overtake and adapt the AlgoWorks helps 3. Copy all help topics into the corresponding directories. Explorer view After the installation the directory B0_01_CFG has the same topics like the overwritten TC_Sources_CFG directory. To overtake all already made country adaptations to the new AlgoWorks configuration you have to copy them manually. 4.
Update procedures 5. Copy the definition files for AlgoWorks into the corresponding directories. Explorer view Copy the AlgoWorks definition files MenuCfgData.xls and TextCfgData.xls 6. Overtake all changes into your new AlgoWorks variant, which were made between Version 1.32.0AB-000 and version 1.35.0-000 (See page 12) See document [3] for additional information. 22 Siemens Building Technologies 007428_b_en_-- Fire Safety & Security Products 05.
Update procedures 8.1.3 The customizing process was NOT started yet Procedure to be followed 1. Remove AlgoWorks version 1.32.0AB-000 by using the setup program. Follow the procedure described in document [3] ’How to remove AlgoWorks’ The folder AW1_3 must be deleted manually. 2. Install the new AlgoWorks version 1.35.0-000 by using the setup program. 8.1.
Update procedures 2. Delete the country specific BDV’s manually. 3. Delete the directory .../TC_Sources_BDV manually. Explorer view Delete the country specific BDV’s manually Delete the directory .../TC_Sources_BDV manually. 4. Install the new BDV’s J0_114x_730_10 by using the setup program on the CD. The new BDV J0_1140_730_10 and J0_1145_730_10 will be installed. 5. Create a new country specific BDV which is based on the just installed one.
Update procedures 8.2.2.2 Major changes Procedure in case of major changes 1. Install the new BDV’s J0_114x_730_10 by using the setup program on the CD. Explorer view New created directories (completely J0-BDV) Unchanged directory New BDV help topics 2. Open the BDV Help project in the directory .../TC_Sources_BDV/HELP/COUNTRY/Source and Overtake all changes into your country variant, which were made between J0_114x_730_08 and J0_114x_730_10.
Update procedures 8.2.3 No prepared BDV's If the country specific adaptations have not been started yet, it is strongly recommended to use the new international BDVs. Procedure 1. Remove BDV version J0_1140_730_08 Follow the procedure described in document [3] ’How to remove BDVs’ 2. Delete the country specific BDV’s manually. 3. Delete the directory .../TC_Sources_BDV manually. 4. Install the new BDV’s J0_114x_730_10 by using the setup program on the CD.
Siemens Switzerland Ltd Building Technologies Group International Headquarters Fire Safety & Security Products Gubelstrasse 22 CH-6301 Zug Tel. +41 41 – 724 2424 Fax +41 41 – 724 3522 www.siemens.com/buildingtechnologies Document no. 007428_b_en_-- Edition 05.